Các lỗi thường gặp

Code :
  • Code: L4-30
  • Description: MFP fan motor trouble
    The motor lock signal is detected during rotation of the MFP fan motor.
  • Causes: Fan motor trouble. Harness connection trouble between the MFPC PWB and the fan motor. MFP circuit trouble.
  • Remedy: Use SIM6-2 to check the rotating operation of the fan. Check the harness and the connector between the MFPC PWB and the fan motor.
  • Code: L4-31
  • Description: Paper exit cooling fan trouble
    The fan operation signal is not detected.
  • Causes: Paper exit cooling fan trouble. PCU PWB trouble Connection trouble of the connector and the harness.
  • Remedy: Check connection of the connectors and the harness. Use SIM6-2 to check the rotating operation of the fan. Replace the paper exit cooling fan. Replace the PCU PWB.
  • Code: L4-32
  • Description: Power source cooling fan trouble
    The fan operation signal is not detected.
  • Causes: Power cooling fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
  • Remedy: Use SIM6-2 to check that the fan is actually rotating. Replace the power cooling fan. Replace the PCU PWB. Check connection of the connectors and the harness.
  • Code: L4-35
  • Description: Fusing cooling fan trouble
    The fan operation signal is not detected.
  • Causes: Fusing cooling fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
  • Remedy: Use SIM6-2 to check that the fan is actually rotating. Replace the fusing cooling fan. Replace the PCU PWB. Check connection of the connector and the harness.
  • Code: L4-43
  • Description: Paper exit cooling fan 2 trouble
    The fan operation signal is not detected.
  • Causes: Paper exit cooling fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
  • Remedy: Replace the fan. Replace the PCU PWB. Check the connector and the harness. Use SIM6-2 to check that the fan is actually rotating.
  • Code: L4-44
  • Description: Power cooling fan 2 trouble
    The lock signal is detected while the power cooling fan is operating.
  • Causes: Power cooling fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
  • Remedy: Use SIM6-2 to check that the fan is actually rotating. Replace the power cooling fan. Replace the PCU PWB. Check the connector and the harness.
  • Code: L4-56
  • Description: Fusing cooling fan 2 trouble
    The fan operation signal is not detected.
  • Causes: Fusing cooling fan 2 trouble PCU PWB trouble. Connection trouble of the connector and the harness.
  • Remedy: Use SIM6-2 to check that the fan is actually rotating. Replace the fusing cooling fan. Replace the PCU PWB. Check the connector and the harness.
  • Code: L6-10
  • Description: Polygon motor trouble
    The polygon motor does not reach the specified RPM within the specified time after starting rotation of the polygon motor.
  • Causes: Polygon motor trouble. LSU mother PWB trouble. Connection trouble of the connector and the harness.
  • Remedy: Use SIM61-1 to check the operation of the polygon motor. Check connection of the connector and the harness. Replace the LSU. Replace the LSU mother PWB.