Description: Power source cooling fan (PSFM1) trouble
Causes: The fan operation signal is not detected within the specified time in the power cooling fan operation. Power cooling fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
Remedy: Use SIM6-2 to check the operation of the fan motor. Replace the power cooling fan. Replace the PCU PWB. Check/replace the connector or the harness.
Causes: When the LSU cooling fan is operated, the fan operation signal is not detected within the specified time. LSU cooling fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
Remedy: Use SIM6-2 to check the operation of the fan motor. Replace the LSU cooling fan. Replace the PCU PWB. Replace the LSU control PWB. Check connection of the connector and the harness.
Description: Paper exit cooling fan (POFM2) trouble
Causes: Paper exit cooling fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
Remedy: Use SIM6-2 to check the operation of the fan motor. Replace the paper exit cooling fan. Replace the PCU PWB. Check connection of the connector and the harness.
Causes: Harness/connector trouble between the PCU PWB and the fan motor. PCU PWB trouble. Fan motor trouble. The fan does not rotate because of the other trouble (No power supply to the fan motor)
Remedy: Use SIM6-2 to check the operation of the fan motor. Replace the fan motor / the PCU PWB. Check connection of the connector and the harness.
Description: Paper exit cooling fan (POFM3) trouble
Causes: The fan operation signal is not detected within the specified time in the paper exit cooling fan operation. Paper exit cooling fan trouble. PCU PWB trouble Connection trouble of the connector and the harness.
Remedy: Check connection of the connector and the harness. Use SIM6-2 to check the operation of the fan motor. Replace the paper exit cooling fan. Replace the PCU PWB.
Description: Power source cooling fan (PSFM2) trouble
Causes: Harness/connector trouble between the PCU PWB and the fan motor. PCU PWB trouble. Fan motor trouble. The fan does not rotate because of the other trouble (No power supply to the fan motor)
Remedy: Use SIM6-2 to check the operation of the fan motor. Check the harness and the connector between the PCU PWB and the fan motor.. Replace the fan motor / the PCU PWB.
Causes: Harness/connector trouble between the PCU PWB and the fan motor. PCU PWB trouble. Fan motor trouble. The fan does not rotate because of the other trouble (No power supply to the fan motor)
Remedy: Use SIM6-2 to check the operation of the fan motor. Check the harness and the connector between the PCU PWB and the fan motor.. Replace the fan motor / the PCU PWB.
Causes: The motor does not reach the specified rpm in 8 sec after starting rotation of the polygon motor. Polygon motor trouble. LSU control PWB trouble. Connection trouble of the connector and the harness.
Remedy: Use SIM61-1 to check the operation of the polygon motor. Check connection of the connector and the harness. Replace the polygon motor. Replace the LSU. Replace the LSU control PWB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.