Remedy: Use SIM49-5 to upload the watermark data. Replace the HDD.
Code: E7-50
Description: Engine connection trouble
Causes: A PWB, or firmware, or LSU which is not supported by the machine specifications is detected in the PCU PWB. PCU PWB trouble. LSU trouble.
Remedy: Check the kind and the version of the firmware. Check the LSU, and replace it if necessary. Check the PCU PWB, and replace it if necessary.
Code: E7-55
Description: PWB information sum error (Engine detection)
Causes: PCU EEPROM sum check error. PCU EEPROM trouble. PCU EEPROM contact trouble. Malfunction due to noises
Remedy: Replace the PCU PWB. Replace the PCU EEPROM.
Code: E7-60
Description: Combination error between the MFP PWB and other PWB, firmware
Causes: A PWB or firmware which is not supported by the machine specifications is detected in the MFP PWB. MFP PWB trouble. The PWB/firmware which is not supported by the machine specifications is connected.
Remedy: Check the kind and the version of the firmware. Check the MFP PWB, and replace it if necessary.
Code: E7-61
Description: Combination error between the MFP PWB and the PCU PWB
Causes: Combination error between the MFP PWB and the PCU PWB. MFP PWB trouble. PCU PWB trouble.
Remedy: Check the combination between the MFP PWB and the PCU PWB. Replace the MFP PWB. Replace the PCU PWB.
Code: E7-65
Description: MFP EEPROM sum check error
Causes: MFP PWB EEPROM device breakdown. Contact trouble of the MFP EEPROM device. Malfunction due to noises.
Remedy: Replace the MFP PWB. Replace the MFP PWB EEPROM.
Remedy: Check connection of the SCU PWB, the MFP PWB, and the mother board. Check the ground. Replace the SCU PWB. Replace the MFP PWB. Replace the mother board.
Remedy: Check connection of the PCU PWB, the MFP PWB, and the mother board. Check the ground. Replace the PCU PWB. Replace the MFP PWB. Replace the mother board.