Các lỗi thường gặp

Code :
  • Code: A0-21
  • Description: Conflict firmware and EEPROM data version (PCU)
  • Causes: Inconsistency between the PCU firmware version and the EEPROM data version.
  • Remedy: Check the combination of the firmware.
  • Code: A0-22
  • Description: Conflict firmware and EEPROM data version (SCU)
  • Causes: Inconsistency between the SCU firmware version and the EEPROM data version.
  • Remedy: Check the combination of the firmware.
  • Code: C1-10
  • Description: Main charger trouble
  • Causes: The main charger unit is not installed properly. There is an abnormality in the main charger unit. Disconnection of the high voltage PWB connector. MC/DV high voltage PWB trouble. PCU PWB trouble
  • Remedy: Check the output of the main charger with SIM8-2. Check disconnection of the main charger./Replace. Check disconnection of the high voltage PWB connector./Replace. Replace the MC/DV high voltage PWB. Replace the PCU PWB.
  • Code: E6-10
  • Description: DSPF (CIS) shading error (Black correction)
  • Causes: Installation error of the CIS unit harness. CIS unit trouble. DSPF PWB trouble.
  • Remedy: Check the installing state of the harness to the CIS unit. Check the CIS unit. Check the DSPF PWB.
  • Code: E6-11
  • Description: DSPF (CIS) shading error (White correction
  • Causes: Installation error of the CIS unit harness. Copy lamp lighting trouble. Dirt on the reference white plate. CIS unit trouble. DSPF PWB trouble. Shading adjustment error
  • Remedy: Check the installing state of the harness the CIS unit. Clean the reference white plate. Check the CIS unit. Check the DSPF PWB.
  • Code: E6-14
  • Description: CIS-ASIC error
  • Causes: DSPF PWB trouble.
  • Remedy: Replace the DSPF PWB.
  • Code: E7-01
  • Description: MFP image data error
  • Causes: Image data transfer error in the MFP PWB. MFP PWB trouble.
  • Remedy: Check connection of the connector and the harness of the MFP PWB. Replace the MFP PWB.
  • Code: E7-03
  • Description: HDD trouble
  • Causes: Connector, harness connection trouble in the MFP PWB and HDD. HDD error file management area data abnormality (FAT breakage). MFP PWB trouble.
  • Remedy: Check connection of the connector and the harness of the MFP PWB and HDD. Use SIM62-2,3 to check read/write operations of the HDD. Replace the HDD. Replace the MFP PWB.