Code :
  • Code: F1-61
  • Description: Inserter/EEPROM trouble
    Data read failure on turning on the power
  • Causes: EEPROM trouble Control circuit runaway due to noises
    Inserter PWB EEPROM access circuit trouble
  • Remedy: Case 1 Cause EEPROM trouble Control circuit runaway due to noises Check and remedy Check that the EEPROM is properly installed. Replace the inserter PWB. Case 2 Cause Inserter PWB EEPROM access circuit trouble Check and remedy Replace the inserter PWB.
  • Code: F1-62
  • Description: Inserter/reverse sensor trouble
    Auto adjustment failure on turning on the power
  • Causes: Harness disconnection. Inserter PWB trouble.
  • Remedy: Use SIM 3-2 to check the sensor operation.
  • Code: F2-00
  • Description: Toner control sensor open
    When the toner sensor output value is detected as smaller than 0.5V or greater than 4.5V for 3 times continuously at every 500ms after completion of the auto development adjustment.
  • Causes: Connector harness trouble Connector not connected.
  • Remedy: Check connection of the toner control sensor. Check connection of the connector harness to the main PWB. Check for disconnection of the harness.
  • Code: F2-02
  • Description: Toner supply abnormality
    Toner remains in the toner bottle when undertoner is detected by the toner concentration sensor in the developing unit.
  • Causes: Toner concentration sensor trouble. Toner remaining quantity sensor trouble. Connector harness trouble for the above sensors.
  • Remedy: Check connector of hopper unit toner motor (TM1) Check connector of toner bottle toner motor (TM2) Check connection of the connector harnesses to the main PWB. Check broken harness for above connections. Check output of the toner concentration sensor (SIM25-1). Check output of the toner remaining quantity sensor (SIM10-2).
  • Code: F2-04
  • Description: Improper cartridge (Life cycle error, etc.)
    An improper toner bottle is inserted. CRUM (IC chip trouble)
  • Causes: IC chip trouble Improper cartridge
  • Remedy: Insert a proper cartridge.
  • Code: F2-05
  • Description: CRUM error
    Communication with the IC chip cannot be made. Data write failure to the CRUM or data read failure from the CRUM occurs 3 times continuously except for toner cartridge installation detection.
  • Causes: IC chip trouble Improper cartridge
  • Remedy: Insert a proper cartridge.
  • Code: F2-06
  • Description: CRUM ID error
    IC chip trouble
  • Causes: Improper cartridge
  • Remedy: Insert a proper cartridge.
  • Code: F2-31
  • Description: Process control trouble (Photoconductor surface reflection rate abnormality)
    Before starting process control, the drum surface is read by the image density sensor to make the sensor gain adjustment so that the output is fixed to a certain level. Though the sensor gain is changed, the output is not fixed to a certain level.
  • Causes: Image density sensor trouble
  • Remedy: Use SIM 44-02 to perform the process control sensor gain adjustment.