Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Sharp MXM623U — Trang 18/22

Code: L6-10

Description: Polygon motor trouble
Causes: The motor does not reach the specified rpm in 8 sec after starting rotation of the polygon motor. Polygon motor trouble. LSU control PWB trouble. Connection trouble of the connector and the harness.
Remedy: Use SIM61-1 to check the operation of the polygon motor. Check connection of the connector and the harness. Replace the polygon motor. Replace the LSU. Replace the LSU control PWB.

Code: L8-01

Description: Full wave signal detection error
Causes: No full wave signal is detected. PCU PWB trouble Power unit trouble. Connection trouble of the connector and the harness.
Remedy: Replace the PCU PWB. Replace the power unit. Check connection of the connector and the harness.

Code: L8-02

Description: Full wave signal error
Causes: An abnormality in the full wave signal frequency is detected. (The frequency is detected as 65Hz or above, or 45Hz or less.) PCU PWB trouble. Power unit trouble. Connection trouble of the connector and the harness. Power frequency, waveform abnormality.
Remedy: Replace the PCU PWB. Replace the power unit. Check connection of the connector and the harness. Check the power waveform.

Code: L8-20

Description: Communication error of MFP PWB/ Mother board
Causes: Mother board PWB - MFP PWB connection trouble. MFP PWB trouble. Mother trouble.
Remedy: Check connection between the mother board and the MFP PWB. Check the ground of the main unit. Replace the MFPC PWB. Replace the mother board.

Code: PC--

Description: Personal counter not detected
Causes: The personal counter is not installed. The personal counter is not detected.
Remedy: Check connection of the connectors and the harness. Replace the SCU PWB.

Code: U1-01

Description: Battery trouble
Backup SRAM battery voltage fall.
Causes: Battery life Battery circuit abnormality
Remedy: Check to confirm that the battery voltage is about 2.0V or above.

Code: U2-00

Description: MFP EEPROM read/write error
Causes: MFP PWB EEPROM trouble. EEPROM socket contact trouble. MFP PWB trouble. Strong external noises.
Remedy: Replace the MFP PWB EEPROM. Replace the MFP PWB. Check the power environment.

Code: U2-05

Description: HDD/MFP PWB SRAM contents inconsistency
Causes: The HDD or the MFP PWB which differs from that before turning OFF the power is installed. HDD trouble. MFP PWB trouble.
Remedy: Use SIM16 to cancel the error. If there is backup data (export data by device cloning), import it.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie