Code :
- Code: E7-62
- Description: Controller connection trouble (scanner)
Controller connection trouble. Compatibility trouble between the controller and the scanner.
- Causes: Combination error between the controller PWB and the engine.
- Remedy: Check the controller PWB. Check combination between the controller PWB and the scanner.
- Code: E7-65
- Description: MFP EEPROM sum check error
EEPROM PWB information sum error
- Causes: EEPROM device trouble. EEPROM device contact trouble. Device access error due to noises.
- Remedy: Replace the PWB.
- Code: E7-70
- Description: Scanner connection trouble
Unknown PWB identification information is detected on the SCU PWB
- Causes: The PWB / firmware which is not supported by the machine specifications is connected. SCU PWB trouble. DSPF PWB trouble.
- Remedy: Check the firmware kind and the version. Check the SCU PWB. Check the DSPF PWB.
- Code: E7-71
- Description: DSPF connection trouble
An unknown PWB identification information is detected in the DSPF PWB/ combination abnormality with the SCU PWB
- Causes: PWB / firmware which does not support the machine specifications is connected.
- Remedy: Firmware kind / Version check.
- Code: E7-75
- Description: DSPF connection trouble
An unknown PWB identification information is detected in the DSPF PWB/ combination abnormality with the SCU PWB
- Causes: PWB / firmware which does not support the machine specifications is connected.
- Remedy: Firmware kind / Version check.
- Code: E7-75
- Description: PWB information sum error (scanner detection)
EEPROM PWB information sum error
- Causes: EEPROM device trouble. EEPROM device contact trouble. Device access error due to noises.
- Remedy: Replace the SCU PWB.
- Code: E7-76
- Description: PWB information sum error (DSPF detection)
FLASH ROM PWB information sum error
- Causes: FLASH ROM device trouble. FLASH ROM device contact trouble. Device access error due to noises.
- Remedy: Replace the DSPF PWB.
- Code: E7-80
- Description: MFP - SCU PWB communication error
- Causes: SCU PWB - MFPC PWB connection trouble. SCU PWB trouble. MFPC PWB trouble.
- Remedy: Check connection of the SCU PWB and the MFPC PWB. Check the ground. Replace the SCU PWB. Replace the MFPC PWB.