Description: Thermistor heater abnormality power-ON: Abnormality service call the thermistor detected when power turned or the temperature the fuser roller does not rise a specified period time after power turned ON.
Remedy: 1. Check the thermistors (1) Check if the connectors are disconnected. (2) Check if the center, side and edge thermistors are in contact with the surface of the fuser roller properly? (3) Check if the harnesses of the center, side and edge thermistors are open circuited. 2. Check the heater (1) Check if the heater is broken. (2) Check if the connector of the heater is disconnected. (3) Check if the thermostat is blown. 3. Check the MAIN board (1) Check if the connectors CN17 are disconnected. (2) Check if the conductor pattern on the MAIN board is short circuited or open circuited. (3) Replace the MAIN board. 4. Clear the status counter After repairing the matter which caused the error [C41], perform the following: (1) Turn ON the power while [0] and [8] are pressed simultaneously. (2) Key in “400”, then press [ENTER]. (3) Change the current status counter value “1” or “2” to “0”, then press [ENTER] (to cancel [C41]). (4) Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.
Code: C43
Description: Thermistor abnormality during warming or ready status after abnormality judgment
Remedy:
Code: C44
Description: Heater abnormality after abnormality judgment: The temperature the fuser roller has exceeded the range control (in this case, the main switch turns OFF automatically) does not even reach the range.
Remedy: 1. Check the thermistors (1) Check if the connectors are disconnected. (2) Check if the center, side and edge thermistors are in contact with the surface of the fuser roller properly? (3) Check if the harnesses of the center, side and edge thermistors are open circuited. 2. Check the heater (1) Check if the heater is broken. (2) Check if the connector of the heater is disconnected. (3) Check if the thermostat is blown. 3. Check the MAIN board (1) Check if the connectors CN17 are disconnected. (2) Check if the conductor pattern on the MAIN board is short circuited or open circuited. (3) Replace the MAIN board. 4. Check the switching regulator (1) Check if the connectors CN108 are disconnected. 5. Clear the status counter Change the current status counter value (08-400) “5”, “7” or “9” to “0” for [C44], taking the same procedure as that for [C41]. * The status counter value is as follows in the following cases. Change them to “0” respectively. • The error occurred during warming-up: “5” • The error occurred after the equipment has become ready: “7” • The temperature detected by the center thermistor is 230°C or higher: “9” • The temperature detected by the side thermistor is 230°C or higher: “9” • The temperature detected by the edge thermistor is 230°C or higher: “9” only during printing.
Code: C45
Description: Thermistor abnormality during printing: Abnormality the thermistor detected during printing.
Remedy: 1. Check the edge thermistor (1) Check if the connector is disconnected. (2) Check if the edge thermistor is in contact with the surface of the fuser roller properly. (3) Check if the harness of the edge thermistor is open circuited. 2. Check the MAIN board (1) Check if the connector CN17 is disconnected. (2) Check if the conductor pattern on the board is short circuited or open circuited. (3) Replace the MAIN board. 3. Clear the status counter Change the current status counter value (08-400) “6” to “0”.
Code: C55, F11
Description: ADF I/F error: Communication error has occurred between the ADF and the scanner
Remedy:
Code: C56
Description: PFC board I/F error: Communication error has occurred between the PFC board and the equipment.
Remedy:
Code: C94
Description: Firmware update error: error message appears when either the following Main boards installed e- STUDIO182/212/242. The Main board for e-STUDIO165/205 which STUDIO167/207/237 firmware installed The Main board for e-STUDIO165/167/205/207/237 which e-STUDIO e-STUDIO182/212/242 firmware installed
Remedy:
Code: C97
Description: High-voltage transformer abnormality: Leakage the main charger detected.
Remedy: (1) the main charger installed securely? (2) Check the spring high-voltage supply contact point deformed. (3) Check the needle electrode broken the main charger grid deformed. (4) Check any foreign matters on the needle electrode the main charger grid. (5) the transfer/separation charger installed securely? (6) Check the transfer/separation charger wire broken unhooked. (7) Check any foreign matter on the transfer/separation charger wire.