Remedy: Are the harness(es) between the PLG board and the galvanomirror, PLG board and laser drive board, and PLG board and HSYNC board broken, and connector(s) disconnected? Yes Replace the harness(es), and re-connect the connector(s). No • Replace the PLG board. • Replace the unit.
Code: CA5
Description: Laser power adjustment error
Remedy: Are the harness(es) between the PLG board and the galvanomirror, PLG board and laser drive board, and PLG board and HSYNC board broken, and connector(s) disconnected? Yes Replace the harness(es), and re-connect the connector(s). No • Replace the PLG board. • Replace the unit.
Code: CA6
Description: Laser PWM calibration error
Remedy: Are the harness(es) between the PLG board and the galvanomirror, PLG board and laser drive board, and PLG board and HSYNC board broken, and connector(s) disconnected? Yes Replace the harness(es), and re-connect the connector(s). No • Replace the PLG board. • Replace the unit.
Code: CA9
Description: Image data transmission error from SYS board
Remedy: Is the harness between the PLG board and the SYS board broken, and connector disconnected? Yes Replace the harness, and re-connect the connector. No • Replace the PLG board. • Replace the SYS board.
Code: CAA
Description: Secondary scanning fine adjustment error
Remedy: Are the harness(es) between the PLG board and the galvanomirror, PLG board and laser drive board, and PLG board and HSYNC board broken, and connector(s) disconnected? Yes Replace the harness(es), and re-connect the connector(s). No • Replace the PLG board. • Replace the unit.
Remedy: Are the harness(es) between the PLG board and the galvanomirror, PLG board and laser drive board, and PLG board and HSYNC board broken, and connector(s) disconnected? Yes Replace the harness(es), and re-connect the connector(s). No • Replace the PLG board. • Replace the unit.
Remedy: Are the harness(es) between the PLG board and the galvanomirror, PLG board and laser drive board, and PLG board and HSYNC board broken, and connector(s) disconnected? Yes Replace the harness(es), and re-connect the connector(s). No • Replace the PLG board. • Replace the unit.
Code: CAD
Description: Primary scanning tap adjustment error
Remedy: Are the harness(es) between the PLG board and the galvanomirror, PLG board and laser drive board, and PLG board and HSYNC board broken, and connector(s) disconnected? Yes Replace the harness(es), and re-connect the connector(s). No • Replace the PLG board. • Replace the unit.