Các lỗi thường gặp

Code :
  • Code: L8-01
  • Description: No full wave signal The zero cross signal is not detected.
  • Causes: Power unit abnormality MCU PWB abnormality
  • Remedy: Check connection of the harness and connectors. Replace the MCU PWB. Replace the power unit.
  • Code: U2-04
  • Description: EEPROM serial communication error EEPROM access process error
  • Causes: EEPROM abnormality
  • Remedy: Check that the EEPROM is properly set. Use SIM 16 to cancel the trouble. Replace the MCU PWB
  • Code: U2-11
  • Description: Counter check sum error (EEPROM) Check sum error of the counter area in the EEPROM
  • Causes: EEPROM abnormality
  • Remedy: Check that the EEPROM is properly set. Use SIM 16 to cancel the trouble. Replace the MCU PWB.
  • Code: U2-12
  • Description: Adjustment value check sum error (EEPROM) Check sum error of the adjustment value area in the EEPROM
  • Causes: EEPROM abnormality
  • Remedy: Check that the EEPROM is properly set. Use SIM 16 to cancel the trouble. Replace the MCU PWB.