Code: L8-01

Description: No full wave signal The zero cross signal is not detected.
Causes: Power unit abnormality MCU PWB abnormality
Remedy: Check connection of the harness and connectors. Replace the MCU PWB. Replace the power unit.

Code: U2-04

Description: EEPROM serial communication error EEPROM access process error
Causes: EEPROM abnormality
Remedy: Check that the EEPROM is properly set. Use SIM 16 to cancel the trouble. Replace the MCU PWB

Code: U2-11

Description: Counter check sum error (EEPROM) Check sum error of the counter area in the EEPROM
Causes: EEPROM abnormality
Remedy: Check that the EEPROM is properly set. Use SIM 16 to cancel the trouble. Replace the MCU PWB.

Code: U2-12

Description: Adjustment value check sum error (EEPROM) Check sum error of the adjustment value area in the EEPROM
Causes: EEPROM abnormality
Remedy: Check that the EEPROM is properly set. Use SIM 16 to cancel the trouble. Replace the MCU PWB.