Causes: An abnormality occurs in communication between the CPU and the IMC. - IMC – CPU signal line abnormality IMC Memory defect/data abnormality - Replace the MCU PWB with new one.
Remedy: Replace the MCU PWB with new one.
Code: E1-10
Description: IMC trouble
Causes: An abnormality occurs in the IMC. - USB chip error/CODEC error on the IMC. - Replace the MCU PWB with a new one.
Remedy: Replace the MCU PWB with a new one.
Code: E1-13
Description: IMC flash ROM error
Causes: An abnormality occurs in the IMC flash ROM. - IMC abnormality - Replace the MCU PWB with a new one. If downloading of the program is abnormally terminated, it may cause an error. Download the program again to avoid this.
Remedy: Replace the MCU PWB with a new one. If downloading of the program is abnormally terminated, it may cause an error. Download the program again to avoid this.
Causes: An installation error occurs in the IMC memory module. An error occurs during access to the IMC memory. - Improper installation of the IMC memory module. - IMC memory module abnormality - IMC memory contact abnormality - IMC abnormality.
Remedy: Check installation of the memory module. Replace the memory module. Replace the MCU PWB with a new one.
Code: E1-81
Description: IMC communication interface error (parity)
Causes: A parity error occurs in communication between the CPU and the IMC. - IMC memory defect/data abnormality
Remedy: Check the memory of the IMC. Replace the MCU PWB with new one.
Code: E1-82
Description: IMC communication interface error (Overrun)
Causes: An overrun error occurs in communication between the CPU and the IMC. - IMC memory defect/data abnormality.
Remedy: Check the memory of the IMC. Replace the MCU PWB with new one.
Code: E1-84
Description: IMC communication interface error (Framing)
Causes: A framing error occurs in communication between the CPU and the IMC. - IMC memory defect/data abnormality.
Remedy: Check the memory of the IMC.
Code: E7-02
Description: LSU trouble
Causes: The BD signal from the LSU cannot be detected in a certain cycle. (Always OFF or always ON) - LSU connector or LSU harness defect or disconnection Polygon motor rotation abnormality Laser beams are not generated. MCU PWB abnormality
Remedy: Check connection of the LSU connector. Execute TC 61-03 to check the LSU operations. Check that the polygon motor rotates normally. Check that the laser emitting diode generates laser beams. Replace the LSU unit. Replace the MCU PWB.