Description: Original was longer than 78.7 in (2m). (Information Code 031 or 032 is printed on the Transaction Journal instead.)
Remedy:
Code: J72
Description: Read Point Sensor does not go ON within 10 seconds after the original starts feeding. (Information Code 030 is printed on the Transaction Journal instead.)
Remedy:
Code: J74
Description: The Exit Sensor does not go ON within a predetermined time after the Sensor is activated.
Remedy:
Code: J75
Description: The Exit Sensor does not go OFF within a predetermined time after the Sensor is activated.
Remedy:
Code: J80
Description: The Automatic Duplex Unit (ADU) Entrance Sensor does not detect paper within a predetermined time.
Remedy:
Code: J82
Description: The ADU Exit Sensor does not detect paper within a predetermined time after ADU Middle Sensor is activated.
Remedy:
Code: J83
Description: The ADU Entrance Sensor keeps detecting paper after a predetermined time has lapsed.
Remedy:
Code: J92
Description: The Original was pulled out when feeding an original.