Description: Power-ON jam: The paper is remaining on the paper transport path when power is turned ON.
Causes: Sensor. MAIN board
Remedy: 1 Open the cover of the unit/ area whose picture is blinking on the control panel. Is there any paper on the transport path? (Refer to the following table.) Yes Remove the paper. No 2 2 Is the sensor in the jamming area working? (Perform the input check in the test mode: refer to the following table.) Yes 3 No • Check if the connector of the sensor is disconnected. • Check if any of the connectors on the MAIN board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor pattern on the MAIN board is short circuited or open circuited. • Replace the sensor 3 MAIN board • Replace the MAIN board. Registration area Right cover Registration sensor 03-[A]/[A] Exit area Right cover Exit sensor 03-[A]/[B] ADU Right cover ADU paper path sensor 03-[1]/[C] PFU PFU side cover PFU drawer feed sensor 03-[4]/[A] PFP PFP side cover PFP upper drawer feed sensor 03-[1]/[E] PFP upper lower feed sensor 03-[2]/[C]
Code: E061
Description: Incorrect paper size setting for 1st drawer: The size of paper in the 1st drawer differs from size setting of the equipment.
Causes:
Remedy: Paper size If any paper remains in the equipment or drawer, remove it. Match the paper size of the drawer setting and the one in the drawer.
Code: E062
Description: Incorrect paper size setting for PFU drawer: The size of paper in the 2nd drawer differs from size setting of the equipment.
Causes:
Remedy: Paper size If any paper remains in the equipment or drawer, remove it. Match the paper size of the drawer setting and the one in the drawer.
Code: E063
Description: Incorrect paper size setting for PFP upper drawer: The size of paper in the 3rd drawer differs from size setting of the equipment.
Causes:
Remedy: Paper size If any paper remains in the equipment or drawer, remove it. Match the paper size of the drawer setting and the one in the drawer.
Code: E064
Description: Incorrect paper size setting for PFP lower drawer: The size of paper in the 4th drawer differs from size setting of the equipment.
Causes:
Remedy: Paper size If any paper remains in the equipment or drawer, remove it. Match the paper size of the drawer setting and the one in the drawer.
Code: E065
Description: Incorrect paper size setting for bypass tray: The size of paper in the bypass tray differs from size setting of the equipment.
Causes:
Remedy: Paper size If any paper remains in the equipment or drawer, remove it. Match the paper size of the drawer setting and the one in the drawer.
Code: E090
Description: Time out jam: Image data to be printed cannot be prepared.
Causes: ADU clutch MAIN board Rollers in the ADU
Remedy: dure Check item Result Measure Next Step 1 Open the ADU. Is there any paper in front of the registration sensor? Yes Remove the paper. No 2 2 Is the registration sensor working? (Perform the input check in the test mode: 03-[A]/ [A]) Yes 3 No • Check if the connector of the registration sensor is disconnected. • Check if the connector CN22 on the MAIN board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor pattern on the MAIN board is short circuited or open circuited. • Replace the 1st registration sensor. • Replace the MAIN board. 3 Is the ADU clutch working? (Perform the output check in the test mode: 03-222) Yes 4 No • Check if the connector of the ADU clutch is disconnected. • Check if the connector CN17 on the MAIN board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor pattern on the MAIN board is short circuited or open circuited. • Replace the ADU clutch. • Replace the MAIN board. 4 Rollers in the ADU • Check the rollers in the ADU. Replace them if they are worn out.
Code: E110
Description: ADU misfeeding (Paper not reaching the registration sensor): The paper which has passed through ADU does not reach the registration sensor during duplex printing.
Causes: ADU clutch MAIN board Rollers in the ADU
Remedy: 1 Open the ADU. Is there any paper in front of the registration sensor? Yes Remove the paper. No 2 2 Is the registration sensor working? (Perform the input check in the test mode: 03-[A]/ [A]) Yes 3 No • Check if the connector of the registration sensor is disconnected. • Check if the connector CN22 on the MAIN board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor pattern on the MAIN board is short circuited or open circuited. • Replace the 1st registration sensor. • Replace the MAIN board. 3 Is the ADU clutch working? (Perform the output check in the test mode: 03-222) Yes 4 No • Check if the connector of the ADU clutch is disconnected. • Check if the connector CN17 on the MAIN board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor pattern on the MAIN board is short circuited or open circuited. • Replace the ADU clutch. • Replace the MAIN board. 4 Rollers in the ADU • Check the rollers in the ADU. Replace them if they are worn out.