Remedy: Compare the serial number of the equipment with a number displayed in 08-995. If they are different, enter the correct serial number at 08-995.
Description: Data Overwrite option (GP-1070) disabled
Remedy: Perform firmware installation (any of OS, HDD, system firmware, PFC firmware, main firmware engine ROM and scanner firmware) using USB media. * When the function of the Data Overwrite option (GP-1070) is deleted from the equipment, the service call “F200” occurs.
Remedy: (1) Check if the conductor pattern on the SLG board is short circuited or open circuited. (2) If there is no problem found in the check (1) above, check the combination of the firmware version of the system ROM, engine ROM and scanner ROM. Reinstall the scanner ROM firmware. (3) If an error occurs after step (2) above has been performed, replace the SLG board.
Remedy: (1) Check if the fan is rotating properly. (2) If not, check if any foreign object is adhered. (3) Is the connector CN112 of the SYS board connected securely? (4) Replace the SYS/HDD cooling fan. (5) Replace the SYS board.