Description: PFP motor abnormality: The PFP motor is not rotating normally. (the case that paper can be fed from any drawer except the PFP)
Causes: PFP motor PFP board LGC board
Remedy: 1 Is the PFP motor working? (Perform the output check: 03-109/159) Yes 2 No • Check if the signal line connector CN503 of the PFP motor is disconnected. • Check if the power line connector CN502 of the PFP motor is disconnected. • Check if the connector CN246 on the PFP board is disconnected. • Check if the signal line connector CN241 on the PFP board is • Check if the power line connector CN242 on the PFP board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the PFP motor board, PFP board and LGC board are short circuited or open circuited. 2 Is the LED on the PFP motor board lit without flashing? Yes 3 No • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the PFP motor board, PFP board and LGC board are short circuited or open circuited. 3 PFP board • Check if the PLL lock signal CN246-8 pin output from the PFP board is always “L” level. • Check if the voltage supplied to the microcomputer input terminal IC5-17 pin is always “L” level.
Code: C130
Description: 1st drawer tray abnormality: The tray-up motor is not rotating or the 1st drawer tray is not moving normally. (the case that paper can be fed from any drawer except the 1st drawer)
Causes: Tray-up motor LGC board Tray-up sensor
Remedy: 1 Does the tray go up? (Perform the output check: 03-242, 243) Yes 2 No • Check if the connector of the tray-up motor is disconnected. • Check if the connector CN348 on the LGC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 2 Is the tray-up sensor working? (Perform the input check: 03-[ALL]OFF/ [4]/[B], /[4]/[A]) Yes 3 No • Check if the connector of the sensor is disconnected. • Check if the connector CN348 on the LGC board is disconnected. • Check if the slit reaches the sensor. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 3 LGC board • Check if the conductor pattern on the LGC board is short circuited or open circuited.
Code: C140
Description: 2nd drawer tray abnormality: The tray-up motor is not rotating or the 2nd drawer tray is not moving normally. (the case that paper can be fed from any drawer except the 2nd drawer)
Causes: Tray-up motor LGC board Tray-up sensor
Remedy: 1 Does the tray go up? (Perform the output check: 03-242, 243) Yes 2 No • Check if the connector of the tray-up motor is disconnected. • Check if the connector CN348 on the LGC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 2 Is the tray-up sensor working? (Perform the input check: 03-[ALL]OFF/ [4]/[B], /[4]/[A]) Yes 3 No • Check if the connector of the sensor is disconnected. • Check if the connector CN348 on the LGC board is disconnected. • Check if the slit reaches the sensor. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 3 LGC board • Check if the conductor pattern on the LGC board is short circuited or open circuited.
Code: C150
Description: PFP upper drawer tray abnormality: The PFP upper drawer tray-up motor is not rotating or the PFP upper drawer tray is not moving normally. (the case that paper can be fed from any drawer except the PFP upper drawer)
Causes: Tray-up motor PFP board LGC board Tray-up sensor
Remedy: 1 Does the tray go up? (Perform the output check: 03-278, 280) Yes 2 No • Check if the connector of the tray-up motor is disconnected. • Check if any of the connectors CN241, CN242 and CN244 on the PFP board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the PFP board and LGC board are short circuited or open circuited. 2 Is the tray-up sensor working? (Perform the input check: 03-[ALL]OFF/ [4]/[B], /[4]/[A]) Yes 3 No • Check if the connector of the sensor is disconnected. • Check if any of the connectors CN241, CN247 and CN248 on the PFP board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the slit reaches the sensor. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the PFP board and LGC board are short circuited or open circuited. 3 LGC board • Check if the conductor pattern on the LGC board is short circuited or open circuited.
Code: C160
Description: PFP lower drawer tray abnormality: The PFP lower drawer tray-up motor is not rotating or the PFP lower drawer tray is not moving normally. (the case that paper can be fed from any drawer except the PFP lower drawer)
Causes: Tray-up motor PFP board LGC board Tray-up sensor
Remedy: 1 Does the tray go up? (Perform the output check: 03-278, 280) Yes 2 No • Check if the connector of the tray-up motor is disconnected. • Check if any of the connectors CN241, CN242 and CN244 on the PFP board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the PFP board and LGC board are short circuited or open circuited. 2 Is the tray-up sensor working? (Perform the input check: 03-[ALL]OFF/ [4]/[B], /[4]/[A]) Yes 3 No • Check if the connector of the sensor is disconnected. • Check if any of the connectors CN241, CN247 and CN248 on the PFP board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the slit reaches the sensor. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the PFP board and LGC board are short circuited or open circuited. 3 LGC board • Check if the conductor pattern on the LGC board is short circuited or open circuited.
Code: C180
Description: LCF tray-up motor abnormality: The LCF trayup motor is not rotating or the LCF tray is not moving normally. (the case that paper can be fed from any drawer except the LCF)
Remedy: 1 Does the tray move? (Perform the output check: 03-271) Yes 2 No • Check if the connector of the LCF tray-up motor is disconnected. • Check if any of the connectors CN100, CN101 and CN103 on the LCF board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 2 Are the LCF tray-up sensor and LCF tray bottom sensor working? (Perform the input check: 03-[ALL]OFF/[0]/[F], /[9]/ [A]) Yes 3 No • Check if the connectors of the sensors are disconnected. • Check if any of the connectors CN100, CN104 and CN105 on the LCF board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the slit reaches the sensors. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 3 LGC board • Check if the conductor pattern on the LGC board is short circuited or open circuited.
Code: C1A0
Description: LCF end fence motor abnormality: The LCF end fence motor is not rotating or the LCF end fence is not moving normally. (the case that paper can be fed from any drawer except the LCF)
Causes: LCF end fence motor LCF board LGC board LCF end fence home position sensor LCF end fence stop position sensor
Remedy: 1 Is the LCF end fence motor working? (Perform the output check: 03-207) Yes 2 No • Check if the connector of the LCF end fence motor is disconnected. • Check if any of the connectors CN100, CN101 and CN103 on the LCF board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 2 Are the LCF end fence home/stop position sensors working? (Perform the input check: 03-[ALL]OFF/[0]/[A], /[0]/ [B]) Yes 3 No • Check if the connectors of the sensors are disconnected. • Check if either of the connectors CN100 or CN107 on the LCF board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the slit reaches the sensors. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 3 LGC board • Check if the conductor pattern on the LGC board is short circuited or open circuited.
Code: C1B0
Description: LCF transport motor abnormality: The LCF transport motor is not rotating normally (when paper can be fed from any drawer except the LCF).
Causes: LCF transport motor LCF board LGC board
Remedy: 1 Is the LCF transport motor working? (Perform the output check: 03-122/172) Yes 2 No • Check if the connector CN112 of the LCF transport motor is disconnected. • Check if the connector CN102 on the LCF board is disconnected. • Check if the signal line connector CN100 on the LCF board is disconnected. • Check if the power line connector CN101 on the LCF board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the connector pins are disconnected or the harnesses are open circuited. 2 LCF transport motor LGC board • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF transport motor board, LCF board and LGC board are short circuited or open circuited. • Check if the PLL lock signal CN102-3 pin output from the LCF board is always “L” level. • Check if the voltage supplied to the microcomputer input terminal IC103-17 pin is always “L” level.