Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Toshiba e-Studio 2555C — Trang 30/36

Code: F100_2

Description: HDD format error: Encryption key data of both the SYS board and the SRAM board for the SYS board are damaged.
Causes:
Remedy: Encryption key status Check the displayed message. ([3] + [C] + [POWER] → 5. Key Backup Restore)

Code: F101_0

Description: HDD connection error (HDD connection cannot be detected.)
Causes: HDD SYS board
Remedy: HDD, SYS board, Setting 1. Turn the power of the equipment OFF and check the connection of the HDD. - Connector and harness check - Check if the connector pins of the HDD are bent. - Check if HDD for other equipment is not installed. - Check if SRAM for other equipment is not installed. 2. If the error still occurs after step 1, perform the following. - Perform [3C] - [5] (Key Backup Restore) and check that each Key Status is "OK". - If not, recover the key (copy "SRAM Key Status" to "FROM Key Status" or vice versa). 3. If the error still persists after step 2, perform the following. - Perform [3C] - [3] (Format HDD), and then install "System Software (HD data)" with [49] - [4]. Notes: The following items will be deleted by performing [3C] - [3] (Format HDD). . Message Log . Job Log . Spool Data (Print, Email reception) . Template If F101_1 occurs with ADI-HDD or the error persists after performing step 3, perform step 3 after performing [4]+[C]+[POWER]→1. Revert factory initial status HDD. 4. If the error persists even after step 3, replace the HDD.

Code: F101_1

Description: Root partition mount error (HDD formatting fails.): The HDD cannot be connected (mounted) caused by damage to the areas in which the program is mainly stored.
Causes: HDD SYS board
Remedy: HDD, SYS board, Setting 1. Turn the power of the equipment OFF and check the connection of the HDD. - Connector and harness check - Check if the connector pins of the HDD are bent. - Check if HDD for other equipment is not installed. - Check if SRAM for other equipment is not installed. 2. If the error still occurs after step 1, perform the following. - Perform [3C] - [5] (Key Backup Restore) and check that each Key Status is "OK". - If not, recover the key (copy "SRAM Key Status" to "FROM Key Status" or vice versa). 3. If the error still persists after step 2, perform the following. - Perform [3C] - [3] (Format HDD), and then install "System Software (HD data)" with [49] - [4]. Notes: The following items will be deleted by performing [3C] - [3] (Format HDD). . Message Log . Job Log . Spool Data (Print, Email reception) . Template If F101_1 occurs with ADI-HDD or the error persists after performing step 3, perform step 3 after performing [4]+[C]+[POWER]→1. Revert factory initial status HDD. 4. If the error persists even after step 3, replace the HDD.

Code: F101_2

Description: Partition mount error: The HDD cannot be connected (mounted) caused by damage to areas other than those described in the F101_1 and F101_4 to F101_9 errors.
Causes: HDD SYS board
Remedy: HDD, SYS board, Setting 1. Turn the power of the equipment OFF and check the connection of the HDD. - Connector and harness check - Check if the connector pins of the HDD are bent. - Check if HDD for other equipment is not installed. - Check if SRAM for other equipment is not installed. 2. If the error still occurs after step 1, perform the following. - Perform [3C] - [5] (Key Backup Restore) and check that each Key Status is "OK". - If not, recover the key (copy "SRAM Key Status" to "FROM Key Status" or vice versa). 3. If the error still persists after step 2, perform the following. - Perform [3C] - [3] (Format HDD), and then install "System Software (HD data)" with [49] - [4]. Notes: The following items will be deleted by performing [3C] - [3] (Format HDD). . Message Log . Job Log . Spool Data (Print, Email reception) . Template If F101_1 occurs with ADI-HDD or the error persists after performing step 3, perform step 3 after performing [4]+[C]+[POWER]→1. Revert factory initial status HDD. 4. If the error persists even after step 3, replace the HDD.

Code: F101_3

Description: Partition mount error: The HDD cannot be connected (mounted) caused by damage to areas other than those described in the F101_1 and F101_4 to F101_9 errors.
Causes: HDD SYS board
Remedy: HDD, SYS board, Setting 1. Turn the power of the equipment OFF and check the connection of the HDD. - Connector and harness check - Check if the connector pins of the HDD are bent. - Check if HDD for other equipment is not installed. - Check if SRAM for other equipment is not installed. 2. If the error still occurs after step 1, perform the following. - Perform [3C] - [5] (Key Backup Restore) and check that each Key Status is "OK". - If not, recover the key (copy "SRAM Key Status" to "FROM Key Status" or vice versa). 3. If the error still persists after step 2, perform the following. - Perform [3C] - [3] (Format HDD), and then install "System Software (HD data)" with [49] - [4]. Notes: The following items will be deleted by performing [3C] - [3] (Format HDD). . Message Log . Job Log . Spool Data (Print, Email reception) . Template If F101_1 occurs with ADI-HDD or the error persists after performing step 3, perform step 3 after performing [4]+[C]+[POWER]→1. Revert factory initial status HDD. 4. If the error persists even after step 3, replace the HDD.

Code: F101_4

Description: Partition mount error: The HDD cannot be connected (mounted) caused by damage to the "/work" partition.
Causes: HDD SYS board
Remedy: HDD, SYS board, Setting 1. Turn the power of the equipment OFF and check the connection of the HDD. - Connector and harness check - Check if the connector pins of the HDD are bent. - Check if HDD for other equipment is not installed. - Check if SRAM for other equipment is not installed. 2. If the error still occurs after step 1, perform the following. - Perform [3C] - [5] (Key Backup Restore) and check that each Key Status is "OK". - If not, recover the key (copy "SRAM Key Status" to "FROM Key Status" or vice versa). 3. If the error persists after step 2, perform [5]+[C]+[POWER]→2. Recovery F/S→3. /work, and then restart the equipment. 4. If the error persists after step 3, perform [5]+[C]+[POWER]→3. Initialize HDD→2. /work, and then restart the equipment. 5. If the error still persists after step 4, perform the following. - Perform [3C] - [3] (Format HDD), and then install "System Software (HD data)" with [49] - [4]. Notes: The following items will be deleted by performing [3C] - [3] (Format HDD). . Message Log . Job Log . Spool Data (Print, Email reception) . Template If the error persists after performing step 5, perform step 5 after performing [4]+[C]+[POWER]→1. Revert factory initial status HDD. 6. If the error persists even after step 5, replace the HDD.

Code: F101_5

Description: Partition mount error: The HDD cannot be connected (mounted) caused by damage to the "/registration" partition.
Causes: HDD SYS board
Remedy: HDD, SYS board, Setting 1. Turn the power of the equipment OFF and check the connection of the HDD. - Connector and harness check - Check if the connector pins of the HDD are bent. - Check if HDD for other equipment is not installed. - Check if SRAM for other equipment is not installed. 2. If the error still occurs after step 1, perform the following. - Perform [3C] - [5] (Key Backup Restore) and check that each Key Status is "OK". - If not, recover the key (copy "SRAM Key Status" to "FROM Key Status" or vice versa). 3. If the error persists after step 2, perform [5]+[C]+[POWER]→2. Recovery F/S→4. /registration, and then restart the equipment. 4. If the error persists after step 3, perform [5]+[C]+[POWER]→3. Initialize HDD→3. /registration, and then restart the equipment. 5. If the error still persists after step 4, perform the following. - Perform [3C] - [3] (Format HDD), and then install "System Software (HD data)" with [49] - [4]. Notes: The following items will be deleted by performing [3C] - [3] (Format HDD). . Message Log . Job Log . Spool Data (Print, Email reception) . Template If the error persists after performing step 5, perform step 5 after performing [4]+[C]+[POWER]→1. Revert factory initial status HDD. 6. If the error persists even after step 5, replace the HDD.

Code: F101_6

Description: Partition mount error: The HDD cannot be connected (mounted) caused by damage to the "/backup" partition.
Causes: HDD SYS board
Remedy: HDD, SYS board, Setting 1. Turn the power of the equipment OFF and check the connection of the HDD. - Connector and harness check - Check if the connector pins of the HDD are bent. - Check if HDD for other equipment is not installed. - Check if SRAM for other equipment is not installed. 2. If the error still occurs after step 1, perform the following. - Perform [3C] - [5] (Key Backup Restore) and check that each Key Status is "OK". - If not, recover the key (copy "SRAM Key Status" to "FROM Key Status" or vice versa). 3. If the error persists after step 2, perform [5]+[C]+[POWER]→2. Recovery F/S→5. /backup, and then restart the equipment. 4. If the error persists after step 3, perform [5]+[C]+[POWER]→3. Initialize HDD→4. /backup, and then restart the equipment. 5. If the error still persists after step 4, perform the following. - Perform [3C] - [3] (Format HDD), and then install "System Software (HD data)" with [49] - [4]. Notes: The following items will be deleted by performing [3C] - [3] (Format HDD). . Message Log . Job Log . Spool Data (Print, Email reception) . Template If the error persists after performing step 5, perform step 5 after performing [4]+[C]+[POWER]→1. Revert factory initial status HDD. 6. If the error persists even after step 5, replace the HDD.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie