Các lỗi thường gặp

Code :
  • Code: C5A6
  • Description: Tray4 Software Error
  • Causes:
  • Remedy: Change the Tray4 Board
  • Code: C5A7
  • Description: When LCF is setting,Tray2 software Error or Tray3 software Error is report from PU. Interchange the error to LCF Software Error by CU. Occur:Detect flash memory software error of Tray.
  • Causes:
  • Remedy: Undetected flash memory software error of Tray3.
  • Code: C5B0
  • Description: Duplex Clock Adjust Error
  • Causes:
  • Remedy: Change the Duplex
  • Code: C5B2, C5B3, C5B4
  • Description: Tray-2/3/4 CPU clock frequency error
  • Causes: C5B2=2nd Tray C5B3=3rd Tray C5B4=4th Tray
  • Remedy: Replace the Tray board GOH-11.
  • Code: C5B5
  • Description: When LCF is setting, Tray2 Clock Adjust Error or Tray3 Clock Adjust Error is report from PU. Interchange the error to LCF Clock Adjust Error by CU.
  • Causes:
  • Remedy: Replace the Tray board
  • Code: C91A, C91B, C91C
  • Description: RFID reader I/F erro
  • Causes: Interface error with the RFID reader is detected. 01: Communication error between the RFID reader and the engine circuit boards. 02: Error in the wireless circuit of the RFID reader 03: Communication error between the RFID reader and the toner cartridge. 04: Error is detected in the RFID toner cartridge. (In more than 4)
  • Remedy: 01: Same as the error no. C91D 02: Replace the RFID R/W board. 03: Check for normal connection of the antenna cable. 04: Check if quantity of the toner cartridge is correct or not.
  • Code: C91D
  • Description: RFID Reader not Installed
  • Causes: RFID read device error Does this error recur?
  • Remedy: Check for normal connection of the RFID R/W board. Replace the RFID R/W. Replace the PU board.
  • Code: C921
  • Description: AC voltage zero-crossing error
  • Causes:
  • Remedy: C h e ck t h e AC voltage. Change the Lowvoltage board or PU board.