Description: Fuser unit related service call IH coil abnormality after abnormality judgment(pre-running end temperature abnormality)
Causes:
Remedy: 1 Power voltage Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) 2 Thermistor • Check if the center and edge thermistor are installed properly. • Check if the harnesses of the center and edge thermistor are open circuited. • Check if the connectors of the center and edge thermistor are disconnected (J1101). 3 Switching regulator and fuser unit • Is the fuser unit installed correctly? • Check if the IH-COIL is broken. • Check if the terminal of the IH-COIL is attached securely. • Check if the thermostat is blown • Check if the drawer connector is damaged or its connection is detected. • Check if the connectors of the power supply unit are disconnected (CN504, CN506). • Check if the power supply unit is abnormal. 4 LGC board • Check if the connectors CN355 and CN357 are disconnected. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 5 Clear the status counter 1. [0]+ [8] Power ON. 2. Key in "2002", then press [START]. 3. Change the current status counter value (08-2002) "5", "6", "7", "9", "22", "23", "24", "25", "27", "29", or "63 to 66". * The status counter value is as follows in the following cases. - The error occurred during warming-up: "5" or "6" The error occurred after the equipment has become ready: "7". - The temperature detected by the center thermistor is 220°C or higher, the temperature detected by the edge thermistor is 235°C or higher : "9", "22", "23", "25", "27" or "29" - The error occurred during printing: "24", "25", or "64 to 66". - The error occurred during energy saving: "27". - A paper jam occurred: "29".
Description: Fuser unit related service call IH coil abnormality after abnormality judgment(pre-running end temperature abnormality)
Causes:
Remedy: 1 Power voltage Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) 2 Thermistor • Check if the center and edge thermistor are installed properly. • Check if the harnesses of the center and edge thermistor are open circuited. • Check if the connectors of the center and edge thermistor are disconnected (J1101). 3 Switching regulator and fuser unit • Is the fuser unit installed correctly? • Check if the IH-COIL is broken. • Check if the terminal of the IH-COIL is attached securely. • Check if the thermostat is blown • Check if the drawer connector is damaged or its connection is detected. • Check if the connectors of the power supply unit are disconnected (CN504, CN506). • Check if the power supply unit is abnormal. 4 LGC board • Check if the connectors CN355 and CN357 are disconnected. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 5 Clear the status counter 1. [0]+ [8] Power ON. 2. Key in "2002", then press [START]. 3. Change the current status counter value (08-2002) "5", "6", "7", "9", "22", "23", "24", "25", "27", "29", or "63 to 66". * The status counter value is as follows in the following cases. - The error occurred during warming-up: "5" or "6" The error occurred after the equipment has become ready: "7". - The temperature detected by the center thermistor is 220°C or higher, the temperature detected by the edge thermistor is 235°C or higher : "9", "22", "23", "25", "27" or "29" - The error occurred during printing: "24", "25", or "64 to 66". - The error occurred during energy saving: "27". - A paper jam occurred: "29".
Description: IH coil abnormality after abnormality judgment(temperature abnormality at ready status)
Causes:
Remedy: 1 Power voltage Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) 2 Thermistor • Check if the center and edge thermistor are installed properly. • Check if the harnesses of the center and edge thermistor are open circuited. • Check if the connectors of the center and edge thermistor are disconnected (J1101). 3 Switching regulator and fuser unit • Is the fuser unit installed correctly? • Check if the IH-COIL is broken. • Check if the terminal of the IH-COIL is attached securely. • Check if the thermostat is blown • Check if the drawer connector is damaged or its connection is detected. • Check if the connectors of the power supply unit are disconnected (CN504, CN506). • Check if the power supply unit is abnormal. 4 LGC board • Check if the connectors CN355 and CN357 are disconnected. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 5 Clear the status counter 1. [0]+ [8] Power ON. 2. Key in "2002", then press [START]. 3. Change the current status counter value (08-2002) "5", "6", "7", "9", "22", "23", "24", "25", "27", "29", or "63 to 66". * The status counter value is as follows in the following cases. - The error occurred during warming-up: "5" or "6" The error occurred after the equipment has become ready: "7". - The temperature detected by the center thermistor is 220°C or higher, the temperature detected by the edge thermistor is 235°C or higher : "9", "22", "23", "25", "27" or "29" - The error occurred during printing: "24", "25", or "64 to 66". - The error occurred during energy saving: "27". - A paper jam occurred: "29".
Description: IH coil abnormality after abnormality judgment(temperature abnormality at high temperature)
Causes:
Remedy: 1 Power voltage Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) 2 Thermistor • Check if the center and edge thermistor are installed properly. • Check if the harnesses of the center and edge thermistor are open circuited. • Check if the connectors of the center and edge thermistor are disconnected (J1101). 3 Switching regulator and fuser unit • Is the fuser unit installed correctly? • Check if the IH-COIL is broken. • Check if the terminal of the IH-COIL is attached securely. • Check if the thermostat is blown • Check if the drawer connector is damaged or its connection is detected. • Check if the connectors of the power supply unit are disconnected (CN504, CN506). • Check if the power supply unit is abnormal. 4 LGC board • Check if the connectors CN355 and CN357 are disconnected. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 5 Clear the status counter 1. [0]+ [8] Power ON. 2. Key in "2002", then press [START]. 3. Change the current status counter value (08-2002) "5", "6", "7", "9", "22", "23", "24", "25", "27", "29", or "63 to 66". * The status counter value is as follows in the following cases. - The error occurred during warming-up: "5" or "6" The error occurred after the equipment has become ready: "7". - The temperature detected by the center thermistor is 220°C or higher, the temperature detected by the edge thermistor is 235°C or higher : "9", "22", "23", "25", "27" or "29" - The error occurred during printing: "24", "25", or "64 to 66". - The error occurred during energy saving: "27". - A paper jam occurred: "29".
Causes: Side cover interlock switch. LGC board FIL board IH board Power supply
Remedy: Power supply • Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) Side cover interlock switch • Connector check (J1008, CN354) • Harness check Fuser unit • Drawer connector check • Thermostat check • Unit check LGC board • Connector check (CN357) • Board check FIL board • Connector check • Board check IH board • Connector check (CN561, CN562, CN563) • Board check Status counter 1. [0], [8] Power ON. 2. Key in “2002”, then press [START]. 3. Change the current status counter value (08-2002) "11" to "0" 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state. Connector and harness • Check the connectors and harnesses of the parts replaced just before C471 occurred. • Check the connectors which connect the equipment and LCF/PFP.
Causes: Side cover interlock switch. LGC board FIL board IH board Power supply
Remedy: Power supply • Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) Side cover interlock switch • Connector check (J1008, CN354) • Harness check Fuser unit • Drawer connector check • Thermostat check • Unit check LGC board • Connector check (CN357) • Board check FIL board • Connector check • Board check IH board • Connector check (CN561, CN562, CN563) • Board check Status counter 1. [0], [8] Power ON. 2. Key in “2002”, then press [START]. 3. Change the current status counter value (08-2002) "11" to "0" 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state. Connector and harness • Check the connectors and harnesses of the parts replaced just before C471 occurred. • Check the connectors which connect the equipment and LCF/PFP.
Description: Surge pressure detection / power and voltage upper limit abnormality
Causes: Power supply IH board
Remedy: Power supply • Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) Fuser unit • Drawer connector check • Thermostat check • Unit check IH board • Connector check (CN357, CN561, CN562, CN563) • Board check Status counter 1. [0], [8] Power ON. 2. Key in “2002”, then press [START]. 3. Change the current status counter value (08-2002) "13" or "16" to "0". 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.
Description: Power and voltage lower limit abnormality
Causes: Power supply IH board
Remedy: Power supply • Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) Fuser unit • Drawer connector check • Thermostat check • Unit check IH board • Connector check (CN357, CN561, CN562, CN563) • Board check Status counter 1. [0], [8] Power ON. 2. Key in “2002”, then press [START]. 3. Change the current status counter value (08-2002) "13" or "16" to "0". 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.