Code: SC226

Description: Laser Synchronization Detector Error 1: C Leading Edge: LD0 While the polygon motor is rotating normally, no synchronizing detection signal is output for LD0 cyan, leading edge, even after the laser diode has been firing for 2 sec.
Remedy: • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Laser synchronizing detector defective • Beam not reflected in photo detection • GAVD (ASIC) on the BICU defective • LD driver board defective • LDB defective • BICU defective • Check board connections, replace

Code: SC227

Description: Laser Synchronization Detector Error 2: C Leading Edge (Other than LD0) While the polygon motor is rotating normally, no synchronizing detection signal is output for cyan, leading edgefor any LD other than LD0, even after the laser diode has been firing for 2 sec.
Remedy: • Beam not reflected in photo detection • GAVD (ASIC) on the BICU defective • LD driver defective • LDB defective • BICU defective • Check board connections, replace

Code: SC230

Description: FGATE error 1: Feedback remains HIGH for K write After the start of timing to create the black image, the PFGATE register of the GAVD (ASIC) does not assert, even after 5 sec. when: • Images are created on the drum. • MUSIC patterns are created on the transfer belt. The BICU received no feedback (LOW signal) from the LD unit to indicate that the lasers started firing at the prescribed time to create the patterns.
Remedy: • GAVD (ASIC) on the BICU defective • PCI I/F on the IPU defective • ASIC on the IOB defective • Controller board disconnected, defective • Harness between the BICU and LDB unit disconnected, loose, or defective. • Check board connections, replace

Code: SC231

Description: FGATE error 1: Feedback remains LOW for K write After the start of timing to create the black image, the PFGATE register of the GAVD (ASIC) does not assert, even after 5 sec. when: • Images are created on the drum. • MUSIC patterns are created on the transfer belt. The BICU received a LOW feedback signal, but the signal remained LOW (indicating the lasers were still operating), even after creation of the next image should have started.
Remedy: • GAVD (ASIC) on the BICU defective • PCI I/F on the IPU defective • ASIC on the IOB defective • Check board connections, replace

Code: SC232

Description: FGATE error 1: Feedback remains HIGH for Y write After the start of timing to create the yellow image, the PFGATE register of the GAVD (ASIC) does not assert, even after 5 sec. when: • Images are created on the drum. • MUSIC patterns are created on the transfer belt. The BICU received no feedback (LOW signal) from the LD unit to indicate that the lasers started firing at the prescribed time to create the patterns.
Remedy: • GAVD (ASIC) on the BICU defective • PCI I/F on the IPU defective • ASIC on the IOB defective • Controller board disconnected, defective • Harness between the BICU and LDB unit disconnected, loose, or defective. • Check board connections, replace

Code: SC233

Description: FGATE error 1: Feedback remains LOW for Y write. After the start of timing to create the yellow image, the PFGATE register of the GAVD (ASIC) does not assert, even after 5 sec. when: • Images are created on the drum. • MUSIC patterns are created on the transfer belt. The BICU received a LOW feedback signal, but the signal remained LOW (indicating the lasers were still operating), even after creation of the next image should have started.
Remedy: • GAVD (ASIC) on the BICU defective • PCI I/F on the IPU defective • ASIC on the IOB defective • Check board connections, replace

Code: SC234

Description: FGATE error 1: Feedback remains HIGH for M write. After the start of timing to create the magenta image, the PFGATE register of the GAVD (ASIC) does not assert, even after 5 sec. when: • Images are created on the drum. • MUSIC patterns are created on the transfer belt. The BICU received no feedback (LOW signal) from the LD unit to indicate that the lasers started firing at the prescribed time to create the patterns.
Remedy: • GAVD (ASIC) on the BICU defective • PCI I/F on the IPU defective • ASIC on the IOB defective • Controller board disconnected, defective • Harness between the BICU LDB unit disconnected, loose, or defective. • Check board connections, replace

Code: SC235

Description: FGATE error 1: Feedback remains LOW for M write. After the start of timing to create the magenta image, the PFGATE register of the GAVD (ASIC) does not assert, even after 5 sec. when: • Images are created on the drum. • MUSIC patterns are created on the transfer belt. The BICU received a LOW feedback signal, but the signal remained LOW (indicating the lasers were still operating), even after creation of the next image should have started.
Remedy: • GAVD (ASIC) on the BICU defective • PCI I/F on the IPU defective • ASIC on the IOB defective • Check board connections, replace