Code: CB80

Description: Backup RAM data abnormality: Abnormality of checksum value on finisher controller PC board is detected when the power is turned ON
Remedy: MJ-1103/1104 Is the error recovered when the power of the equipment is turned OFF and then back ON? YES End. NO Replace the finisher control PC board.

Code: CB81

Description: Flash ROM abnormality: Abnormality of checksum value on finisher controller PC board is detected when the power is turned ON. [MJ-1103/1104]
Remedy: MJ-1103/1104 Is the error recovered when the power of the equipment is turned OFF and then back ON? YES End. NO 1. Check if the conductor pattern on the finisher controller PC board is open circuited or short circuited. 2. Replace the finisher control PC board.

Code: CB82

Description: Finisher - Main CPU program error
Remedy: 1. Update the firmware version of the finisher control PC board (FIN). 2. Replace the finisher control PC board (FIN).

Code: CB83

Description: Saddle Stitch Finisher - Main CPU program error
Remedy: 1. Update the firmware version of the saddle control PC board (ADL). 2. Replace the saddle control PC board (SDL).

Code: CB84

Description: Hole Punch Unit - Main CPU program error
Remedy: Is the firmware version of the PNC board (HP) latest? YES Update the firmware of the PNC board (HP). NO Replace the hole punch control PC board (HP).

Code: CB91

Description: Saddle Stitch Finisher flash ROM abnormality
Remedy: Is the error recovered when the power of the equipment is turned OFF and then back ON? YES End. NO 1. Check if the conductor pattern on the saddle controller PC board (SDL) is open circuited or short circuited. 2. Replace the saddle control PC board (SDL).

Code: CB92

Description: Saddle Stitch Finisher RAM abnormality
Remedy: Is the error recovered when the power of the equipment is turned OFF and then back ON? YES End. NO Replace the Saddle control PC board (SDL).

Code: CB93

Description: Additional folding motor abnormality
Remedy: Is there any mechanical problem when the additional folding carrier is moved? YES Fix the mechanism. NO Is the harness between the additional folding motor (M20) and the CN18 of the saddle control PC board (SDL) disconnected or open circuited? l YES • Reconnect the connector securely if there is any disconnection. • Replace the harness if open circuited. NO 1. Replace the additional folding motor (M20). 2. Replace the saddle control PC board (SDL).