Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Toshiba e-Studio 5540c — Trang 10/44

Code: C963

Description: Connection detection error between the IMG board and the LGC board
Causes:
Remedy: 1 LGC board Connector check (CN319, CN320) 2 IMG board Connector check (CN423, CN424, CN426) 3 Harness between the IMG board and the LGC board Harness check 4 Harness between the IMG board and the low-voltage power supply Harness check
Harness between the IMG board and the LGC board LGC board If the problem is not corrected by the replacement of the LGC board, reinstall the removed LGC board and replace the IMG board. IMG board If the problem is not still corrected by the replacement of the IMG board, reinstall it and ask a specialist to repair it. (Abnormal ID) Harness between the IMG board and the low-voltage power supply

Code: C970

Description: High-voltage transformer abnormality: Leakage of the main charger is detected.
Causes: Main charger
Remedy: Main charger • Install check • Check if any foreign matter is on the needle electrode or main charger grid. • Harness check EPU tray (process unit) • Check if any foreign matter is adhering on the high-voltage terminal of the EPU tray. • Check if there is a sign of discharge on the joint of the high-voltage terminal of the EPU tray and the main charger. Correct if there is.

Code: C9E0

Description: Connection error between SLG board and SYS board
Causes: SLG board If the problem is not corrected with the replacement of the SLG board, reinstall the removed SLG board and replace the IMG board. IMG board If the problem is still not corrected with the replacement of the IMG board, reinstall the removed IMG board and replace the SYS board. SYS board
Remedy: SLG board • Connector check (CN12) • Board check IMG board • Connector check (CN421, CN422) • Board check SYS board • Connector check (CN135) • Board check

Code: CA00

Description: Image position alignment abnormality
Causes:
Remedy: < Invalidating image position alignment control > 1 [0] [8] Power ON 2 [4546] [START] 3 Set the value to “0” (not performed automatically). 4 Power OFF < Checking the abnormal status on image position alignment > 5 [0] [5] Power ON 6 [4720] [START] 7 Press the [START] button again, then check the displayed value. (05-4720-0: Displaying the cause of image position alignment detection error front and rear sides.) When the error [CA00] occurs, the value between 1 and 255 is displayed. (0: Detection normality on the front and rear sides) (The statues of total 8 sections (4 colors on the front and rear sides) are displayed.) 1 :Y on the rear side detection abnormality (*1) 2 : Y on the front side detection abnormality (*1) 3 : Y on the front and rear sides detection abnormality 4 : M on the rear side detection abnormality (*1) 8 : M on the front side detection abnormality (*1) 12 : M on the front and rear sides detection abnormality 16 : C on the rear side detection abnormality (*1) 32 : C on the front side detection abnormality (*1) 48 : C on the front and rear sides detection abnormality 64 : K on the rear side detection abnormality (*1) 85 : All colors on the rear side detection abnormality → (I) 128: K on the front side detection abnormality (*1) 170: All colors on the front side detection abnormality → (I) 192: K on the front and rear sides detection abnormality 255: All colors on the front and rear sides detection abnormality → (I) Other than the above: Multiple colors detection abnormality (*2) The adjustment value is the sum of (*1), which, as in the example below, specifies the cause of the detection abnormality. (E.g. 1) 05-4720-0 --- in case of 72 72 = 64 + 8 → K on the rear side / M on the front side detection abnormality (E.g. 2) 05-4720-0 --- in case of 146 146 = 128 + 18 = 128 + 16 + 2 → K on the front side / C on the rear side / Y on the front side detection abnormality 8 Press the [START] button 9 After [1] is pressed, then press the [START] button. 10 Check the displayed value. (05-4720-1: Displaying the cause of image position alignment detection error center side.) When the error [CA00] occurs, the value between 1 and 85 is displayed. (0: Detection normality on the center side) (The statues of total 4 sections (4 colors on the front and rear sides) are displayed.) 1 : Y on the center side detection abnormality (*3) 4 : M on the center side detection abnormality (*3) 16 : C on the center side detection abnormality (*3) 64 : K on the center side detection abnormality (*3) 85 : All colors on the center side detection abnormality → (I) Other than the above: Multiple colors detection abnormality (*4) The adjustment value is the sum of (*3), which, as in the example below, specifies the cause of the detection abnormality. (E.g. 1) 05-4720-1 --- in case of 65 65 = 64 + 1 → K on the center side / Y on the center side detection abnormality 11 If the adjustment value fits (I) in step 7 or 10, proceed to step (12). In other cases, proceed to step (30). →

Code: CA10

Description: Polygonal motor abnormality: The polygonal motor is not rotating normally.
Causes: Polygonal motor Laser unit cooling fan (front) Laser unit cooling fan (rear) LGC board Laser optical unit
Remedy: Polygonal motor Laser optical unit • Motor check (Perform the output check: 03-103) • Connector check (CN207) • Harness check Laser unit cooling fan (front) • Fan motor check (Perform the output check: 03-437) • Connector check • Harness check • Check if the suction areas of the laser unit cooling fan (front) and the laser unit cooling fan (rear) are plugged up. Laser unit cooling fan (rear) • Fan motor check (Perform the output check: 03-439) • Connector check • Harness check Polygonal motor • Motor check (Perform the output check: 03-103) • Connector check • Harness check LGC board • Connector check (CN329) • Board check Other • Perform the troubleshooting procedures for when an image control related/process related service call or an image failure occurs.

Code: CA20

Description: H-Sync detection error: H-Sync signal detection PC board cannot detect laser beams.
Causes: LGC board Laser optical unit
Remedy: Laser optical unit. • Connector check (relay connector CN212) • Harness check LGC board • Connector check (CN321, CN326) • +5V check (CN302 - 7pin) Check should be performed after the front cover and ADU are closed. • Board check Other • Check if the equipment is grounded.

Code: CA47

Description: SNS board abnormality: The SNS board does not operate due to disconnection or the harness breaking.
Causes: LGC board Laser optical unit
Remedy: Relay connector • Connector check (CN212) CNV board • Connector check • Harness check • Board check LGC board • Connector check (CN321) • Board check

Code: CB00

Description: Finisher not connected: Communication error has occurred between the equipment and finisher. [MJ-1103/1104]
Causes: Finisher control board. LGC board
Remedy: Harness (MFP - Finisher) • Connector check • Harness check Finisher control board • Connector check • Board check F/W Update the finisher firmware. F/W Update the Converter firmware. LGC board • Connector check • Board check