Các lỗi thường gặp

Code :
  • Code: F105
  • Description: Other HDD errors
  • Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are broken. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.
  • Code: F106
  • Description: Point and Print partition damage
  • Remedy: (1) Turn the power OFF and start up the Setting Mode (08). (2) Key in “662” and press the [START] button. (Partition clearing is performed.) (3) Restart the equipment. (4) Access TopAccess. Click the [Administration] tab, and then click the Maintenance Menu to open. Then install the “Point and Print” driver.
  • Code: F107
  • Description: /BOX partition damage
  • Remedy: Initialize the Electronic Filing using the Setting Mode (08-666).
  • Code: F108
  • Description: /SHA partition damage
  • Remedy: Initialize the shared folder using the Setting Mode (08-667).
  • Code: F110
  • Description: Communication error between System-CPU and Scan-ner-CPU
  • Remedy: (1) Check if the connector CN102, CN103 on the SYS board is disconnected. (2) Check if the connector CN10 on the SLG board is disconnected. (3) Check if the harness connecting the SYS board and SLG board is disconnected or open circuited. (4) Check if the harness connecting the SYS board and LGC board is disconnected or open circuited. (5) Check the version of the system ROM on the SYS board. (6) Check the version of the engine ROM version on the LGC board. (7) Check the version of the scanner ROM version on the SLG board. (8) Replace the SYS board. (9) Replace the SLG board. (10) Replace the LGC board.
  • Code: F111
  • Description: Scanner response abnormality
  • Remedy: (1) Check if the connector CN102, CN103 on the SYS board is disconnected. (2) Check if the connector CN10 on the SLG board is disconnected. (3) Check if the harness connecting the SYS board and SLG board is disconnected or open circuited. (4) Check if the harness connecting the SYS board and LGC board is disconnected or open circuited. (5) Check the version of the system ROM on the SYS board. (6) Check the version of the engine ROM version on the LGC board. (7) Check the version of the scanner ROM version on the SLG board. (8) Replace the SYS board. (9) Replace the SLG board. (10) Replace the LGC board.
  • Code: F120
  • Description: Database abnormality: Databases do not run normally.
  • Remedy: (1) Rebuild the databases. (Perform 08-684.) (2) If the error is not recovered, initialize the HDD. (Enter “2” at 08-690.)
  • Code: F130
  • Description: Invalid MAC address
  • Remedy: Compare the serial number of the equipment with a number displayed in 08-995. If they are different, enter the correct serial number at 08-995.
‹ First  < 26 27 28 29
popup

Số lượng:

Tổng tiền:

Danh mục