Description: Waste toner transport motor locking error: The auger in the waste toner transport path does not rotate.
Causes: Waste toner transport motor Auger lock detection sensor EPU board LGC board
Remedy: EPU tray (process unit) • Pull out the process unit, rotate the gear counterclockwise and check if the load is extremely heavy. • Is the load still extremely heavy after the gear is rotated for a while to discharge the toner from the waste toner transport path? • Is the load still extremely heavy after the actuator is removed, the auger is pulled out and clean them? Waste toner transport motor (M31) • Motor check (Perform the output check: 03-234) • Connector check • Harness check Auger lock detection sensor (S42) • Sensor check (Perform the input check: K: 03-[FAX]ON/[0]/[B]) • Connector check • Harness check EPU board • Connector check (CN551, CN557) • Board check LGC board • Connector check (CN308, CN331) • Board check
Remedy: TRU waste toner box • Check if the TRU waste toner box is full of used toner. Replace it, if it is full. TRU waste toner amount detection sensor (S13) • Sensor check (Perform the input check: K: 03-[ALL]OFF/[5]/[E]) • Connector check • Harness check ADU board • Connector check (CN491, CN497) • Board check PFC board • Connector check (CN511) • Board check