Description: RADF original feed motor abnormality: An error signal has been detected when the motor is rotating
Remedy: 1. Check if the connector CN76 on the RADF board is disconnected from the RADF original feed motor or the harnesses are open-circuited. Correct if this is the case. 2. Replace the RADF original feed motor.
Description: RADF read motor abnormality: An error signal has been detected when the motor is rotating.
Remedy: 1. Check if the connector CN76 on the RADF board is disconnected from the RADF read motor or the harnesses are open-circuited. Correct if this is the case. 2. Replace the RADF read motor.
Description: RADF original reverse motor abnormality: An error signal has been detected when the motor is rotating.
Remedy: 1. Check if the connector CN77 on the RADF board is disconnected from the RADF original reverse motor or the harnesses are open-circuited. Correct if this is the case. 2. Replace the RADF original reverse motor.
Description: RADF original exit motor abnormality: An error signal has been detected when the motor is rotating
Remedy: 1. Check if the connector CN78 on the RADF board is disconnected from the RADF oiginal exit motor or the harnesses are open-circuited. Correct if this is the case. 2. Replace the RADF original exit motor.
Description: RADF original reading start sensor abnormality: The automatic adjustment for the original reading start sensor has been performed, but is ended unsuccessfully.
Remedy: Is the “Call for Service” displayed even after the power is turned OFF and back ON? → NO → Leave it and see what happens. YES 1. Check if the circuit pattern between the Engine-CPU and FROM is short circuited or open circuited. 2. Replace the LGC board if this error occurs frequently.
Description: High-voltage transformer leakage abnormality: The high-voltage leakage of the main charger is detected.
Remedy: (1) Is the main charger installed securely? (2) Check if the spring of high-voltage supply contact point is deformed. (3) Check if the main charger wire is broken or the main charger grid is deformed. (4) Check if any foreign matters is on the main charger win or the main charger grid. (5) Replace the High-voltage transformer. (6) Replace the LGC board.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.