Code: 005-500

Description: DADF Write Error During Download RAP Job Fail. An error has occurred during the process of writing data to the DADF-ROM (During Download. Not able to carry out normal operation because ROM content is missing.
Remedy: Retry job. If retry failed, replace the DADF PWB (PL 51.2) and perform download again.

Code: 005-906

Description: DADF Feed Out Sensor Static Jam RAP The DADF Feed Out Sensor turns ON at the following timings. 1. When Power is ON 2. At Feeder Cover Interlock Close 3. At Platen Interlock Close
Remedy: Check the following: • Check the DADF Feed Out Sensor for remaining paper, the Actuator for return failure, foreign substances, contamination on sensors, and etc. • DADF Feed Out Sensor: Component Control [005-205] (PL 51.6) • Check the sw version of the controller sw - update if required • If the problem persists, check the circuit between the DADF Feed Out Sensor and the DADF PWB. If no problems are found, replace the DADF PWB (PL 51.2).

Code: 005-907

Description: DADF Pre Registration Sensor Static Jam RAP The DADF Pre Registration Sensor turns ON at the following timings: 1. When Power is ON 2. At Feeder Cover Interlock Close 3. At Platen Interlock Close
Remedy: Check the following: • Check the DADF Pre Registration Sensor for remaining paper, the Actuator for return failure, foreign substances, contamination on sensors, and etc. • DADF Pre Registration Sensor: Component Control [005-206] (PL 51.17) • Check the sw version of the controller sw - update if required • If the problem persists, check the circuit between the DADF Pre Registration Sensor and the DADF PWB. If no problems are found, replace the DADF PWB (PL 51.2).

Code: 005-913

Description: DADF Inverter Sensor Static Jam RAP The DADF Invert Sensor turns On at the timings below. 1. When Power is ON 2. At Feeder Cover Interlock Close 3. At Platen Interlock Close
Remedy: Check the following: • Check the DADF Inverter Sensor for remaining paper, the Actuator for return failure, foreign substances, contamination on sensors, and etc. • DADF Invert Sensor: Component Control [005-211] (PL 51.9) • Check the sw version of the controller sw - update if required • If the problem persists, check the circuit between the DADF Invert Sensor and the DADF PWB. If no problems are found, replace the DADF PWB (PL 51.2).

Code: 005-915

Description: DADF APS Sensor 1 Static Jam RAP The DADF APS Sensor 1 turns ON at the timings below. 1. When Power is ON 2. At Feeder Cover Interlock Close 3. At Platen Interlock Close
Remedy: Check the following: • Check the DADF APS Sensor 1 for remaining paper, the Actuator for return failure, foreign substances, contamination on sensors, and etc. • DADF APS Sensor 1: Component Control [005-218] (PL 51.17) • Check the sw version of the controller sw - update if required • If the problem persists, check the circuit between the DADF APS Sensor 1 and the DADF PWB. If no problems are found, replace the DADF PWB (PL 51.2).

Code: 005-916

Description: DADF APS Sensor 2 Static Jam RAP The DADF APS Sensor 2 turns ON at the timings below. 1. When Power is ON 2. At Feeder Cover Interlock Close 3. At Platen Interlock Close
Remedy: Check the following: • Check the DADF APS Sensor 2 for remaining paper, the Actuator for return failure, foreign substances, contamination on sensors, and etc. • DADF APS Sensor 2: Component Control [005-219] (PL 51.17) • Check the sw version of the controller sw - update if required • If the problem persists, check the circuit between the DADF APS Sensor 2 and the DADF PWB. If no problems are found, replace the DADF PWB (PL 51.2).

Code: 005-917

Description: DADF APS Sensor 3 Static Jam RAP The DADF APS Sensor 3 turns ON at the timings below. 1. When Power is ON 2. At Feeder Cover Interlock Close 3. At Platen Interlock Close
Remedy: Check the following: • Check the sw version of the controller sw - update if required • Check the DADF APS Sensor 3 for remaining paper, the Actuator for return failure, foreign substances, contamination on sensors, and etc. • DADF APS Sensor 3: Component Control [005-220] (PL 51.17) • If the problem persists, check the circuit between the DADF APS Sensor 3 and the DADF PWB. If no problems are found, replace the DADF PWB (PL 51.2). • Check the sw version of the controller sw - update if required

Code: 005-940

Description: DADF No Original RAP Operation Fail. Final document correction notification due to DADF document being pulled out.
Remedy: • Reload the document. • Change the system data 700-530 to "0" and disable the automatic startup boot operation at System Fail (make sure to reset to 1 when complete • Check the sw version of the controller sw - update if required