Code: 59.C0
Display: 59.C0 Error
Description: The developer-disengagement motor experienced a rotational error.
Remedy: 1. Perform the Alienation Motor test in the Component Tests menu in the Troubleshooting menu. Verify that the cartridges are being correctly alienated. 2. Check the following connectors: J25 at the motor (M10), J261 and J251 on the high voltage power supply-D PCA, and connectors J138 and J106 on the DC controller PCA. 3. Perform the Manual Sensor Test and observe item G. The normal state is “0”. Locate the in-line connector J70 in the cable that is connected to developinghome- position sensor (SR11). To find this connector, remove the left-side cover and look in the area below the support plate. Disconnect the in-line connector. The state of item G should change to “1”. 4. If the motor is defective, replace motor M10. If the sensor is defective, replace the main-drive assembly.