Code: 50.7
Display: 50.7 FUSER ERROR
Description: The fuser has experienced a pressure release mechanism error.
Remedy: 1. Reconnect the connectors of the fuser motor (J1720), fuser unit home-position sensor (J1965), intermediate (J1964), and the DC controller PCA (J105, J121). 2. Test the fuser pressure-release sensor by performing the paper-path test or the manual sensor test in the DIAGNOSTICS menu. 3. Check the sensor flag of the fuser pressure-release sensor. If the sensor flag is damaged, Replace the fuser. 4. Perform the fuser motor and fuser pressure-release-motor component tests in the DIAGNOSTICS menu. 5. Replace the fuser motor. 6. Replace the fuser.