Code: 66.12.11
Display: 66.12.11
Description: Finisher error: swing motor (M36) and the swing-guide home-position sensor (PI35) Occurs when the swing guide does not leave its home position (swing-guide home-position sensor: PI35) after the swing motor (M36) is activated for 3 seconds. Also occurs when the swing guide does not return to its home position (swing-guide home-position sensor: PI35) after the swing motor (M36) is activated for 3 seconds.
Remedy: Control panel diagnostics: M36 (Swing Motor) and PI35 (Swing Guide Home Position Sensor) 1. Test the swing motor M36 by using the finisher component test from the controlpanel display. NOTE: When activated during the component test, the motor should rotate for about five seconds. While the motor is rotating, make sure that the swing guide is moving up or down at the exit area for stapling and stacking. • If the swing guide freely moves up and down, proceed to the next step (testing the swing-guide sensor PI35). • If the swing guide does not freely move up and down, remove the finisher rear cover and use your hand to turn the gear located to the right of motor M36 clockwise. • If the swing guide moves upward, the gears are properly working. Replace motor M36. If after replacing the motor the motor still does not turn on, replace the stacker controller PCA. • If the swing guide does not move, inspect the gears and replace damaged components as necessary. 2. Test the swing-guide sensor PI35 by using the finisher component test from the control-panel display. NOTE: Manually lift the swing guide to the highest position, and then look at the control-panel display and verify a change in state for the sensor. • If the sensor state does not change, perform the following steps: • Verify that the connector J707 on the stacker controller PCA is fully seated and not damaged. • Manually activate the sensor PI35 at the sensor body. If the control panel does not indicate a change of state, replace the sensor. • If raising the swing guide does not activate the sensor but it can be manually activated at the sensor body, replace the swing-guide assembly. • If the PI35 sensor state does change, check the drive gears for damage or obstructions. Replace components as necessary.