Code: 0800
Description: Power Supply (+36V, +24V, +12V)
The power supplies of +36, +24 and +12 V were diagnosed and could not be detected.
The power supplies of +36, +24 and +12 V were diagnosed and could not be detected.
Remedy: • Open the Electronics Cover and check LED 11 and LED 13. • If both LED 11 and LED 13 are OFF, then try the following: – Check the Interlock Switches to make sure they are installed/connected correctly. Make sure that the Rear Cover lips (that activate the Interlock Switches) are not bent and that the Rear Cover is closed correctly. – If the Interlock Switches are installed and connected correctly, then replace the Main PCA • If both LED 11 and LED 13 are ON, then try the following: – Check whether the correct voltages are supplied from the power source (refer to the table below). If the correct voltages are not supplied, then replace the Power Supply Unit – It is possible that this error occurred because of a faulty Main PCA. Replace the Main PCA – Check whether the motors have been short-circuited by testing +24 V. If +24 V is not supplied then replace both Scan-Axis/Paper-Axis Motors. If error continues, replace the Main PCA