Code: 119x
Description: Head Relay Variable Supply Error
Output voltages of the Head Relay Board are abnormal.
Output voltages of the Head Relay Board are abnormal.
Remedy: • Check whether 36V is supplied to the Main PCA. If not, then: – Make sure that the Rear Cover is closed. – Replace Power Supply Unit • Preset the Head Relay Board Voltage from the Diagnostic Menu. Use a circuit tester to check the voltages of the channels that have an error. • If the voltage is supplied, it means that the voltage check circuit is defective. Replace the Main PCA • If the voltage is not supplied, replace the Head Relay Board • There is a possibility of a short circuit off the Head Relay Board output line. Perform a short circuit test on the Main PCA. • Make sure the Carriage Trailing Cable is connected correctly and is not damaged.