Description: Trailing Cable does not seem to be detected.
Remedy: • Check that the Trailing Cable is not damaged. • Check that the Trailing Cable is correctly connected to the Carriage PCA, Interconnect PCA and to the Gamut PCI PCA. • Replace the Gamut PCI PCA. • Replace the Ink Supply Tubes and Trailing Cable. • Replace the Carriage PCA. Only replace one component at a time and check if the error has gone before replacing another component. Using this procedure you will be able to determine exactly which component failed.