Remedy: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • If the System Error continues, replace the Gamut PCI PCA.
Remedy: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Replace the Gamut PCI PCA. • If the System Error continues, replace the Main PCA. Only replace one component at a time and check if the error has gone before replacing another component. Using this procedure you will be able to determine exactly which component failed.
Remedy: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Check that the cables between the PrintMech PCA and the Gamut PCI PCA are not damaged and are correctly connected. • Replace the PrintMech PCA. • If the System Error continues, replace the Gamut PCI PCA. Only replace one component at a time and check if the error has gone before replacing another component. Using this procedure you will be able to determine exactly which component failed.
Description: ISS PCA faulty - Humidity sensor out of scale or NVM backup failure.
Remedy: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • If the System Error continues, replace the Ink Supply Tubes and Trailing Cable.
Remedy: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Check that the Trailing Cable is not damaged. • Check that the Trailing Cable is correctly connected to the Carriage PCA, Interconnect PCA and to the Gamut PCI PCA. • Replace the Carriage PCA. • If the System Error continues, replace the Gamut PCI PCA. Only replace one component at a time and check if the error has gone before replacing another component. Using this procedure you will be able to determine exactly which component failed.
Remedy: • Check that the Carriage Stopper is correctly installed (Refer to Carriage Disassembly Instructions, Step 16.). • Replace the Carriage Assembly. • If the System Error continues, replace the Encoder Strip and Encoder Sensor. Only replace one component at a time and check if the error has gone before replacing another component. Using this procedure you will be able to determine exactly which component failed.
Remedy: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Perform the Electronics Modules Test to troubleshoot the problem further. • If the System Error continues, replace the Power Supply Unit.
Remedy: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Replace the CPU Fan. • If the System Error continues, replace the Main PCA. Only replace one component at a time and check if the error has gone before replacing another component. Using this procedure you will be able to determine exactly which component failed.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.