Code: 0B0002
Description: Bad IDS pressure read.
Remedy: • Check that the cable from the Ink Supply Station (ISS) PCA to the Ink Supply Station is correctly connected. • Check that the Air Pressurization System Sensor Cable is correctly connected and is NOT damaged. • Check all the tubes of the APS and make sure they are NOT pinched or damaged. • Faulty APS. Replace the APS • If the error code continues, replace the Main PCA WARNING Only replace one component at a time and check if the error has gone before replacing another component. Using this procedure you will be able to determine exactly which component failed.