Mã lỗi A2–2410, A2–2610 — Samsung ProXpress M4583FX

Code: A2–2410, A2–2610

Display: Fan Failure: #A2-xxxx. Turn off then on. Call for service if the problem persists
Description: SMPS or Fuser or LSU or Deve fan is not operational.
Remedy: NOTE • SMPS fan error : A2–1210 • Main(Fuser) fan error : A2–2110 • LSU fan error : A2–2410 • Deve fan error : A2–2610 1) Turn the machine off. 2) Check if the corresponding fan connector is connected correctly 3) If the connection is OK, Enter SVC mode and execute fan test. (Diagnostics > Engine Diagnostics > Engine Test Routines) 4) If the fan is not operational, measure the fan power. a) If 24V power is generated, replace the defective fan. • SMPS fan : JC31–00153A • Main(Fuser) fan : JC31–00088A • LSU fan : JC31–00086A • Deve fan : JC31–00086A b) If 24V power is not generated, • Measure the 24V power on the SMPS board. If the SMPS board(JC44-00092C (220V) / JC44-00091C (110V)) is defective, replace it. • If the SMPS board is normal, replace the main board(JC92–02722A). 5) If the fan operation is normal but the error persists, a) Check the yellow line signal with DVM. b) Check fan operation as connected or disconnected. • If the Lock signal is 0V continually, check the harness. If the harness is OK, replace the main board. • If the signal value is different from the table above, replace the fan.