Code: C255C
Description: TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 Reinstall developing unit. 3 Reinstall toner bottle. 4 Check the contact of developing unit for proper connection and correct as necessary. 5 Check the connector between TCRSB CN29-relay CN28-PRCB CN24 for proper connection and correct as necessary. 6 Check the connector between M3-PRCB CN8 for proper connection and correct as necessary. 7 Check the connector between M4-relay CN13-PRCB CN8 for proper connection and correct as necessary. 8 M3 operation check. 9 M4 operation check. 10 Change developing unit. 11 Change TCRSB. 12 Change PRCB.