Các lỗi thường gặp

Code :
  • Code: C0001
  • Description: LCT communication error
    • Due to malfunctioning of the software or other causes, the watchdog timer triggers a reset when time is up.
  • Remedy: 1 Turn OFF the main power switch, wait for 10 sec. or more, and turn ON the main power switch. 2 PCCB51 replacement
  • Code: C0202
  • Description: Tray 1 feeder up/down abnormality
    • The paper feed tray 1 upper limit sensor (PS12) is not blocked even after the lapse of a given period of time after the lifting motion has been started.
  • Remedy: 1 Check the connector between M11-PRCB CN12 for proper connection and correct as necessary. 2 Check the connector of M11 for proper drive coupling and correct as necessary. 3 Check the connector between PS12-relay CN1-PRCB CN13 for proper connection and correct as necessary. 4 PS12 I/O check. 5 M11 operation check. 6 Change M11. 7 Change PRCB.
  • Code: C0204
  • Description: Tray 2 feeder up/down abnormality
    • The paper feed tray 2 upper limit sensor (PS22) is not blocked even after the lapse of a given period of time after the lifting motion has been started.
  • Remedy: 1 Check the connector between M21-PRCB CN11 for proper connection and correct as necessary. 2 Check the connector of M21 for proper drive coupling and correct as necessary. 3 Check the connector between PS22-relay CN6-PRCB CN14 for proper connection and correct as necessary. 4 PS22 I/O check. 5 M21 operation check. 6 Change M21. 7 Change PRCB.
  • Code: C0206
  • Description: Tray 3 lift-up failure
    • The tray 3 upper limit sensor (PS33) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
  • Remedy: 1 Check the connector between M33- PCCB31 CN4 for proper connection and correct as necessary. 2 Check the connector between M43- PCCB31 CN8 for proper connection and correct as necessary. 3 Check the connector between PS33-relay CN18-PCCB31 CN6 for proper connection and correct as necessary. 4 Check the connector between PS43-relay CN18-PCCB31 CN10 for proper connection and correct as necessary. 5 Check the connector of each motor for proper drive coupling, and correct as necessary. 6 PS33 I/O check, sensor check. 7 PS43 I/O check, sensor check. 8 M33 operation check. 9 M43 operation check. 10 Change PRCB31. 11 Change PRCB.
  • Code: C0208
  • Description: Tray 4 lift-up failure
    • The tray 4 upper limit sensor (PS43) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
  • Remedy: 1 Check the connector between M33- PCCB31 CN4 for proper connection and correct as necessary. 2 Check the connector between M43- PCCB31 CN8 for proper connection and correct as necessary. 3 Check the connector between PS33-relay CN18-PCCB31 CN6 for proper connection and correct as necessary. 4 Check the connector between PS43-relay CN18-PCCB31 CN10 for proper connection and correct as necessary. 5 Check the connector of each motor for proper drive coupling, and correct as necessary. 6 PS33 I/O check, sensor check. 7 PS43 I/O check, sensor check. 8 M33 operation check. 9 M43 operation check. 10 Change PRCB31. 11 Change PRCB.
  • Code: C0209
  • Description: LCT elevator motor failure
    • The elevator motor sensor (PS5A) cannot detect both edges of H/L even after the set period of time has elapsed while the elevator motor (M55) is turning backward/forward (raise/lower).
  • Remedy: 1 Check the connector between M55- PCREYB CN2 for proper connection and correct as necessary. 2 Check the connector between PS5APCREYB CN2 for proper connection and correct as necessary. 3 Check the connector of M55 for proper drive coupling, and correct as necessary. 4 PS5A I/O check, sensor check. 5 M55 operation check. 6 Change PCREYB. 7 Change PCCB.
  • Code: C0210
  • Description: LCT lift failure
    • The lift-up upper limit sensor (PS54) is not blocked even after the set period of time has elapsed after the paper lift-up operation began. • The lift-up upper limit sensor (PS54) is not blocked even after the set pulse is detected by the elevator motor sensor (PS5A) after the paper lift-up operation began. • The lift-down lower limit sensor (PS5D) is not unblocked even after the set pulse is detected by the elevator motor sensor (PS5A) after the paper lift-up operation began. • The lift-up upper limit sensor (PS54) is not blocked even after the set period of time has elapsed after the paper lift-up operating. • The lift-down lower limit sensor (PS5D) is not blocked even after the set period of time has elapsed after the paper lift-down operation began. • The lift-down lower limit sensor (PS5D) is not blocked even after the set pulse is detected by the elevator motor sensor (PS5A) after the paper lift-down operation began. • The lift-up upper limit sensor (PS54) is not unblocked even after the set pulse is detected by the elevator motor sensor (PS5A) after the paper lift-down operation began. • The lift-down over run sensor (PS57) is blocked while the paper lift-down operating.
  • Remedy: 1 Check the connector between PS54-relay CN20-PCCB51 PJ5 for proper connection and correct as necessary. 2 Check the connector between PS5DPCREYB CN2 for proper connection and correct as necessary. 3 Check the connector between PS5APCREYB CN2 for proper connection and correct as necessary. 4 Check the connector between PS57- PCREYB CN2 for proper connection and correct as necessary. 5 PS54 I/O check, sensor check. 6 PS5D I/O check, sensor check. 7 PS5A I/O check, sensor check. 8 PS57 I/O check, sensor check. 9 Change PCCB51
  • Code: C0211
  • Description: Manual feed up/down abnormality
    • Paper does not unblock the manual lift-up position sensor (PS83) even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position. • The manual lift-up position sensor (PS83) is not blocked even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position.
  • Remedy: 1 Check the connector between M1-PRCB CN3 for proper connection and correct as necessary. 2 Check the connector of M1 for proper drive coupling and correct as necessary. 3 Check the connector between PS83-PRCB CN9 for proper connection and correct as necessary. 4 Check the connector between SD81-relay CN99-relay CN15-PRCB CN9 for proper connection and correct as necessary. 5 PS83 I/O check, sensor check. 6 SD81 operation check. 7 M1 operation check. 8 Change M1. 9 Change PRCB.