Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 3423-121.29 — Konica-Minolta bizhub 4050

Code: 3423-121.29

Description: Fuser warm-up trouble
Fuser failed to reach pre-heat temperature for motor start during warm up.
Causes: • Controller board (CTLB) • Power supply unit (PU)
Remedy: 1 Check the fuser cables JTHERM1 and JEXIT for proper connection to the CTLB. Reseat the cables if any abnormality is found. 2 Check the cable PCN5 for proper connection to power supply. Reseat the cables if any abnormality is found. 3 Check the cables JTHERM1, JEXIT and PCN5 for damage. Replace the fuser unit if any abnormality is found. 4 Check for resistance on the fuser cable. 1. Turn off the printer. 2. Remove the rear door and cover. 3. Disconnect the fuser cable connected to PCN5 of PU. 4. Check for approximate correct resistance on the fuser cable: 220V/43Om, 110V/10U, 100V/8Om