Description: Tray 1 feeder up/down abnormality
Pick/lift motor: Encoder Never Detected in tray 1.
Causes: • Pick/lift motor gearbox • Controller board (CTLB)
Remedy: 1 Remove Tray 1. 2 Check the lift plate and gears for proper operation by moving the metal plate. Replace the tray 1 if any abnormality is found 3 Check the pick/lift motor gearbox for the following: • Gear tooth breakage • Freedom of rotation Replace the pick/lift motor gearbox if any abnormality is found. 4 Check the cable JLIFT1 on the CTLB. Replace the pick/lift motor gearbox if any abnormality is found. 5 Replace the printer.
Remedy: 1 Check the cable J11 on PFCB. Reseat the cable if any abnormality is found. 2 Remove the option tray insert and bypass PS35. 3 Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation] -> [Paper Passage Test] -> [Tray 2], and press the Start key. 4 Check the ACM for proper operation. Replace the ACM assembly if any abnormality is found. 5 Check the ACM gear for any wear or damage. Replace the ACM assembly if any abnormality is found.
Remedy: 1 Check the cable J11 on PFCB. Reseat the cable if any abnormality is found. 2 Remove the option tray insert and bypass PS35. 3 Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation] -> [Paper Passage Test] -> [Tray 2], and press the Start key. 4 Check the ACM for proper operation. Replace the ACM assembly if any abnormality is found. 5 Check the ACM gear for any wear or damage. Replace the ACM assembly if any abnormality is found.
Remedy: 1 Check the cable J11 on PFCB. Reseat the cable if any abnormality is found. 2 Remove the option tray insert and bypass PS35. 3 Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation] -> [Paper Passage Test] -> [Tray 2], and press the Start key. 4 Check the ACM for proper operation. Replace the ACM assembly if any abnormality is found. 5 Check the ACM gear for any wear or damage. Replace the ACM assembly if any abnormality is found.
Description: Tray 2 feeder up/down abnormality
Separator/Pass-through motor no first encoder
Causes: • PF control board (PFCB) • Separator roll assembly
Remedy: 1 Remove the option tray insert. 2 Check the separator roll assembly gear under the tray base for the following: • Gear tooth breakage • Freedom of rotation Replace the tray 2 if any abnormality is found. 3 Check the cable J10 on the PFCB. Replace the tray 2 if any abnormality is found. 4 Check the separator roll assembly for wear or damage. Replace the separator roll assembly if any abnormality is found.
Description: Tray 2 feeder up/down abnormality
Separator/Pass-through motor stop error
Causes: • PF control board (PFCB) • Separator roll assembly
Remedy: 1 Remove the option tray insert. 2 Check the separator roll assembly gear under the tray base for the following: • Gear tooth breakage • Freedom of rotation Replace the tray 2 if any abnormality is found. 3 Check the cable J10 on the PFCB. Replace the tray 2 if any abnormality is found. 4 Check the separator roll assembly for wear or damage. Replace the separator roll assembly if any abnormality is found.
Causes: • PF control board (PFCB) • Separator roll assembly
Remedy: 1 Remove the option tray insert. 2 Check the separator roll assembly gear under the tray base for the following: • Gear tooth breakage • Freedom of rotation Replace the tray 2 if any abnormality is found. 3 Check the cable J10 on the PFCB. Replace the tray 2 if any abnormality is found. 4 Check the separator roll assembly for wear or damage. Replace the separator roll assembly if any abnormality is found.
Remedy: 1 Check the cable J11 on the PFCB. Reseat the cable if any abnormality is found. 2 Remove the option tray insert and bypass PS35. 3 Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation] -> [Paper Passage Test] -> [Tray 2], and press the Start key. 4 Check the ACM for proper operation. Replace the ACM assembly if any abnormality is found. 5 Check the ACM gear for any wear or damage. Replace the ACM assembly if any abnormality is found
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.