Description: Engine communication error
Controller communication failure - the zero crossing signal used for fuser control in the low voltage (LV) power supply has failed, or the wrong low voltage power supply has been installed.
Causes: • Power supply unit (PU) • Controller board (CTLB)
Remedy: 1 Check the power cord for continuity. If necessary replace. 2 Make sure the nominal voltage source is within specification. • Low-voltage models: 100 to 127 V AC • High-voltage models: 220 to 240 V AC 3 Check if power supply cable is properly connected to the CTLB. Reseat the cables if any abnormality is found. 4 Measure the resistance between terminals A and D of the power supply socket. 1. Turn off the printer. 2. Remove the power cord. 3. Measure the resistance between terminals A and D of PU socket. 4. Is the resistance approximately 30 ohms? 5 Replace the PU if any abnormality is found in the measured resistance. 6 Replace the CTLB.