Mã lỗi 5102-140.10 — Konica-Minolta bizhub 4050

Code: 5102-140.10

Description: Main motor failure to turn
Main motor halls not detected.
Causes: • Main drive gearbox • Main motor (M1) • Controller board (CTLB)
Remedy: 1 Remove the main drive gearbox and check for any debris. 2 Remove the debris if any abnormality is found. 3 Check the gears of main drive gearbox for wear or damage. Replace the main drive gearbox if any abnormality is found. 4 Check M1 for proper operation. 1. Remove the main drive gearbox. Note: Do not disconnect the main drive gearbox cable. 2. Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation Test] -> [Paper Passage Test], and select any of the feed sections. 3. Check if M1 rotates when doing the feed test. 5 Replace the CTLB. 6 Replace the main drive gearbox.