Code: 6751
Description: CCD clamp/gain adjustment failure
During the CCD gain adjustment, a condition in which the peak value of the output data is equal to, or less than, 64 occurs three consecutive times during retries.
During the CCD gain adjustment, a condition in which the peak value of the output data is equal to, or less than, 64 occurs three consecutive times during retries.
Causes: • Scanner unit • Controller board (CTLB)
Remedy: 1 Check the connector between scanner unit-CTLB J101 for proper connection and correct as necessary. 2 Check for possible extraneous light and correct as necessary. 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty. 4 Correct reflective mirror of the scanner if faulty, or change scanner mirror. 5 Replace scanner unit 6 Replace CTLB