Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C1181 — Konica-Minolta bizhub 423

Code: C1181

Description: Malfunctioning of belt up/ down movement
<When FS-529 is installed> • The belt position sensor (PS13) is not turned OFF after the set period of time has elapsed after the belt retract solenoid (SD5) is turned ON. • The belt position sensor (PS13) is not turned ON after the set period of time has elapsed after the conveyance motor/1 (M5) is turned ON.
Remedy: 1 Check the connector between M5-FSCB CN17 for proper connection and correct as necessary. 2 Check the connector between SD5-FSCB CN19 for proper connection and correct as necessary. 3 Check the connector between PS13-FSCB CN7 for proper connection and correct as necessary. 4 Check the connector of M5 for proper drive coupling, and correct as necessary. 5 PS13 I/O check, sensor check. 6 M5 operation check. 7 Change M5. 8 SD5 operation check. 9 Change SD5. 10 Change FSCB.