Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC21-01 — Konica-Minolta bizhub 920 pro

Code: SC21-01

Description: • When the charge cleaning home sensor (PS41) is OFF with the main power switch (SW1) ON, PS41 does not turn ON within a specified period of time after the charge cleaning motor (M23) turns ON for home position research operation (return operation). At this time, an error detection signal (blowout of ICP) is not detected. • PS41 does not turn OFF within a specified period of time after the reverse operation (return operation) is started. At this time, an error detection signal (blowout of ICP) is not detected. • It is checked that the time for the M23 operations is over. The charge cleaning limit sensor (PS42) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS41 being OFF. Or, PS41 does not turn ON within a specified period of time after PS42 turns ON. At this time, an error detection signal (blowout of ICP) is not detected.
Causes: Charge cleaning motor (M23) Printer control board (PRCB) Charge cleaning home sensor (PS41) Charge cleaning limit sensor (PS42) Wiring harness broken Loose connection

← Xem tất cả mã lỗi Konica-Minolta bizhub 920 pro