Mã lỗi C-2104 — Konica-Minolta bizhub 950 pro

Code: C-2104

Description: It is checked that the operations of the transfer/separation cleaning motor (M18) are over. When the transfer/separation cleaning home sensor (PS11) is OFF with the main power switch (SW1) ON, PS11 does not turn ON within a specified period of time after the M18 turns ON for a home position research operation (return operation). At this time, an error detection signal (blowout of ICP) is not detected. PS11 does not turn OFF within a specified period of time after the reverse operation (return operation) is started. At this time, an error detection signal (blowout of ICP) is not detected. It is checked that the operations of the M18 are over. The transfer/ separation cleaning limit sensor (PS12) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS11 being OFF. Or, PS11 does not turn ON within a specified period of time after PS12 turns ON. At this time, an error detection signal (blowout of ICP) is not detected.
Causes: Confirmation of the wiring harness and the connector Transfer/separation cleaning motor (M18) Transfer/separation cleaning home sensor (PS11) Transfer/separation cleaning limit sensor (PS12) ADU drive board (ADUDB)