Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub 950 pro

Code: C-0001

Description: I/O initial communication check in the printer control board (PRCB). Main body drive serial input abnormality 1. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive unit.
Causes: Printer control board (PRCB)

Code: C-0002

Description: Main body drive serial input abnormality 2. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive unit.
Causes: Printer control board (PRCB)

Code: C-0003

Description: Main body drive serial input abnormality 3. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive unit.
Causes: Printer control board (PRCB)

Code: C-0004

Description: Main body drive serial input abnormality 4. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive unit.
Causes: Printer control board (PRCB)

Code: C-0005

Description: Main body drive serial input abnormality 5. Within a specified period of time after the power ON ACK, a serial data is not received from the main body drive board.
Causes: Printer control board (PRCB)

Code: C-0010

Description: Communication error check between the printer engine system boards. Drive communication reception error detection abnormality. A reception error interruption occurs while in the drive board serial data reception. Or, due to the occurrence of the data checksum error/ID information error, a retransmission request is made 3 times and an error is detected on the 4th time.
Causes: Confirmation of the wiring harness and the connector ADU drive board (ADUDB) LU drive board (LUDB) Printer control board (PRCB)

Code: C-0020

Description: Initial communication check between the ADU drive board (ADUDB)/ printer control board (PRCB). ADU drive serial input abnormality 1. Within a specified period of time after the ACK at the time of the main power switch (SW1) being turned ON, a serial data from ID = 0 of the ADUDB is not received.
Causes: Confirmation of the wiring harness and the connector ADU drive board (ADUDB) Printer control board (PRCB)

Code: C-0021

Description: Communication error check between the ADU drive board (ADUDB)/ printer control board (PRCB). ADU drive serial input abnormality 2. Within a specified period of time after the ACK at the time of the main power switch (SW1) being turned ON, a serial data from ID = 7 of the ADUDB is not received.
Causes: Confirmation of the wiring harness and the connector ADU drive board (ADUDB) Printer control board (PRCB)