Mã lỗi C1112 — Konica-Minolta bizhub C227

Code: C1112

Description: Stapler motor malfunction (When FS-534SD is installed) • The stapler home sensor is not turned ON even after the set period of time has elapsed while the stapler motor is energized. • The stapler home sensor is not turned OFF even after the set period of time has elapsed after the stapler home sensor is turned ON.
Causes: • Staple unit • SD drive board (SDDB) • FS control board (FSCB)
Remedy: 1. Check the connector between the staple unit-SDDB J4 for proper connection and correct as necessary. 2. Check the connector of the staple unit for proper drive coupling and correct as necessary. 3. Replace the staple unit. 4. Replace SDDB. 5. Replace FSCB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.20. C1112)