Description: Pre-eject drive motor malfunction (When FS-534 or FS-534SD is installed) • The pre-eject home sensor (PS21) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON. • The pre-eject away sensor (PS22) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON.
Causes: • Pre-eject drive motor (M9) • Pre-eject home sensor (PS21) • Pre-eject away sensor (PS22) • FS control board (FSCB)
Remedy: 1. Check the connector between M9-relay CN7<A>-FSCB J13 for proper connection, and correct as necessary. 2. Check the connector of M9 for proper drive coupling and correct as necessary. 3. Check the connector between PS21-relay CN8-relay CN7<B>-FSCB J12 for proper connection, and correct as necessary. 4. Check the connector between PS22-relay CN8-relay CN7<B>-FSCB J12 for proper connection, and correct as necessary. 5. PS21 I/O check, sensor check • Control signal: FSCB J12-6 (ON) • Location of electrical component: FS-534 6-C 6. PS22 I/O check, sensor check • Control signal: FSCB J12-9 (ON) • Location of electrical component: FS-534 6-C 7. M9 operation check • Control signal: FSCB J13-3 to 4 • Location of electrical component: FS-534 8-C to D 8. Replace M9. 9. Replace FSCB. NOTICE • Link to the wiring diagram (N.2.6 FS-534) • Link to the layout drawings for related parts by each trouble code (S.27. C1144)