Description: Abnormally high toner density detected cyan TCR sensor. The TC ratio of the toner determined by the toner replenishment control is detected to be the predetermined value or over for consecutive times.
Remedy: 1. Reinstall the imaging unit. 2. Reinstall the developing unit/K. 3. Check the connector between the imaging unit or developing unit/K-relay CN161,CN162,CN163,CN164-relay CN15-MFPB CN18E for proper connection and correct as necessary. 4. Replace the the corresponding imaging unit. 5. Replace the developing unit/K. 6. Replace MFPB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.44. C2552, C2559, C2561, C2A11) • Link to the layout drawings for related parts by each trouble code (S.46. C2554, C255A, C2562, C2A12) • Link to the layout drawings for related parts by each trouble code (S.48. C2556, C255B, C2563, C2A13) • Link to the layout drawings for related parts by each trouble code (S.42. C2414, C2558, C255C, C2564)