Description: Fusing sensor wire breaks detection (Edge of the heating roller). After a predetermined period of time after the warm-up stage is started, the heating roller thermistor/1 (TH1) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time.
Causes: • Fusing unit • C3922: Heating roller thermistor/1 (TH1) • C3925: Heating roller temperature sensor (TEMS) • C3926: Heating roller thermistor/2 (TH2) • DC power supply (DCPU) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the connector between the fusing unit-relay CN4-MFPB CN16E for proper connection and correct as necessary. 4. Replace the fusing unit. 5. Replace DCPU. 6. Replace MFPB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.55. C3722, C3922) • Link to the layout drawings for related parts by each trouble code (S.56. C3725, C3825, C3925) • Link to the layout drawings for related parts by each trouble code (S.57. C3726, C3826, C3926)