Mã lỗi C6103 — Konica-Minolta bizhub C227

Code: C6103

Description: Slider over running. The scanner home sensor (PS201) detects the scanner at its home position during a period of time that begins with the time when a prescan command and a scan preparation command are executed and ends when a home return command is executed.
Causes: • Scanner home sensor (PS201) • Scanner motor (M201) • MFP board (MFPB)
Remedy: 1. Correct or change the scanner drive (pulley, gear, belt) if it is faulty. 2. Correct the scanner motor set screw if loose. 3. Adjust [Image Position: Leading Edge] and [Sub Scan Zoom Adj.]. 4. Check the connector between M201-relay CN151-MFPB CN25E for proper connection and correct as necessary. 5. Check the connector between PS201-MFPB CN21E for proper connection and correct as necessary. 6. PS201 I/O check, sensor check • Control signal: MFPB CN21E-15 (ON) • Location of electrical component: 22-J 7. M201 operation check • Control signal: MFPB CN25E-1 to 4 • Location of electrical component: 21-J 8. MFPB F15E conduction check 9. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub C287/C227) • Link to the layout drawings for related parts by each trouble code (S.67. C6102, C6103)